장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나 은행 455-910025-42804

Gas Turbine and Transmitter Systems with ATEX Enclosures

SYS/FTBG-100 Series

Gas Turbine and Transmitter Systems with ATEX Enclosures | SYS/FTBG-100 Series

Gas Turbine and Transmitter Systems with ATEX Enclosures

페이지 하단에서 가격을 확인하세요.

1 year warranty CE
  • Outstanding Accuracy
  • Hybrid Ceramic Bearings for Superior Life
  • DC or AC (Optional) Power
  • Pulse and Analog Output
  • Optional Hi and Lo Alarms
  • Factory Configured
  • Windows® Configuration Software (Included)
  • Nist Certificate Standard
터빈 / 회차 유량계 - 관련 제품 보기

설명

OMEGA’s high accuracy Gas Turbine Series measures the volumetric flow of gas through a pipeline. Gas flowing through the meter turns the turbine rotor at an angular velocity which is proportional to the velocity of the gas being measured. As the turbine rotor turns, the rotor blades pass a non-intrusive pickup coil that generates an electrical signal, referred to as a pulse. Each pulse represents a specific volume of gas (i.e. ACF/AM3). The totalization of these pulses results in the total volumetric flow. The total volume can be converted to mass flow total (SCF or NM3) using reference conditions and base density, or by applying various correction techniques. Standard calibrations for these gas turbine systems are performed at a reference density of 0.1 lb/Ft3. A 10-point calibration certificate (traceable to NIST or other recognized national laboratory) is supplied with each meter. Standard calibration includes a calculated K-factor for gas that is derived from a 10-point NIST calibration for water. Calibrations at customer’s actual operating densities can be performed with special order. OMEGA’s gas turbine flowmeters offer high accuracy measurement of gases for a wide variety of applications, including fiscal measurement, plant cost allocation, energy consumption/conservation, etc. These gas turbine systems are suitable for all non-corrosive gases such as natural gas, air and nitrogen. Special versions of this series are available for use on corrosive gases, such as “off-gas” and feature NACEMR175 trim and self-lubricated ceramic ball bearings. Contact OMEGA for further details. An OMEGA™ gas turbine flowmeter should be chosen so that it is operated within its most accurate range. The capacity of a turbine flowmeter is based on the actual volumetric flow rate and is expressed as actual cubic feet (ACF) or actual cubic meters (AM3). The lower limit of operation is a function of the gas density and velocity.

SPECIFICATIONS (TURBINE)
Over-range: 150% of maximum flow (intermittently)
Turn Down Range: Dependent on gas density at user’s operating conditions
Linearity: ±1% of reading typical
Repeatability: ±0.25% over tabulated repeatable range
Available Temperature Range: -157 to 149°C (-250 to 300°F) continuous
End Fittings (Standard): NPT
Bearing Styles: Self-lubricating, ceramic hybrid ball bearings
Materials: 316/316L dual rated stainless steel with 17.4 pH rotor

SPECIFICATIONS (SIGNAL CONDITIONER)
Input Signal Type: MCP pickup
Input Frequency Range: 0.2 Hz to 4 KHz
Signal Level: 10 mV rms to 30 Vdc
Power Supply: 13 to 30 Vdc standard, 100 to 240 Vac (-AC) (optional), reverse polarity protection
Analog Output: 4 to 20 mA, 1 to 5V, 24 mA overflow condition (dip switch selectable)
Load Resistance: Max 650 Ù @ 24 Vdc
Accuracy: °0.02% of full scale
Temperature Drift: 40 ppm/°C
Pulse Output: 0 to 5V Recommended Minimum Load
Resistance: 50 KÙ
Pulse Scaling: Divide by 1,10,100 per flow unit of measure
Hi/Lo Alarm (Optional): Relay (2A, 30 Vdc), 0 to 5V, open collector (0.5A, 30V)
Communications: RS232 port for configuration and diagnostics
Linearization: Up to 20 points
Operating Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 0 to 90% non-condensing
Enclosure: Extruded aluminum explosion-proof ATEX
Port: 3/4-14 NPT
Regulatory: CE compliant
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
Gas Turbine and Signal Conditioner Systems
  
SYS/FTBG-101/FLSC-C3
4,202,950원
배송: 10 주
 
0.25' Meter, 0.5 NPT, 30° Blade Angle
  
SYS/FTBG-102/FLSC-C3
4,202,950원
배송: 10 주
 
0.25' Meter, 0.5 NPT, 15° Blade Angle
  
SYS/FTBG-103/FLSC-C3
4,202,950원
배송: 10 주
 
0.375' Meter, 0.5 NPT, 30° Blade Angle
  
SYS/FTBG-104/FLSC-C3
4,202,950원
배송: 10 주
 
0.375' Meter, 0.5 NPT, 15° Blade Angle
  
SYS/FTBG-105/FLSC-C3
4,202,950원
배송: 10 주
 
0.625' Meter, 0.75 NPT, 30° Blade Angle
  
SYS/FTBG-106/FLSC-C3
4,202,950원
배송: 8 주
 
0.625' Meter, 0.75 NPT, 15° Blade Angle
  
SYS/FTBG-107/FLSC-C3
4,444,010원
배송: 2 주
 
0.75' Meter, 0.75 NPT, 30° Blade Angle
  
SYS/FTBG-108/FLSC-C3
4,444,010원
배송: 9 주
 
0.75' Meter, 0.75 NPT, 15° Blade Angle
  
SYS/FTBG-109/FLSC-C3
4,649,620원
배송: 10 주
 
1' Meter, 1 NPT, 30° Blade Angle
  
SYS/FTBG-110/FLSC-C3
4,649,620원
배송: 10 주
 
1' Meter, 1 NPT, 15° Blade Angle
  
SYS/FTBG-111/FLSC-C3
4,819,780원
배송: 9 주
 
1.5' Meter, 1.5 NPT, 30° Blade Angle
  
SYS/FTBG-112/FLSC-C3
4,819,780원
배송: 9 주
 
1.5' Meter, 1.5 NPT, 15° Blade Angle
  
SYS/FTBG-113/FLSC-C3
5,069,350원
배송: 10 주
 
2' Meter, 2 NPT, 30° Blade Angle
  
SYS/FTBG-114/FLSC-C3
5,069,350원
배송: 9 주
 
2' Meter, 2 NPT, 15° Blade Angle
  
SYS/FTBG-115/FLSC-C3
6,874,470원
배송: 10 주
 
3' Meter, 3 NPT, 30° Blade Angle
  
SYS/FTBG-116/FLSC-C3
6,874,470원
배송: 9 주
 
3' Meter, 3 NPT, 15° Blade Angle
Turbine and Signal Conditioner Systems with Optional Hi/Lo Alarm
  
SYS/FTBG-101/FLSC-C3-AL
4,615,590원
배송: 10 주
 
0.25' Meter, 0.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-102/FLSC-C3-AL
4,615,590원
배송: 10 주
 
0.25' Meter, 0.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-103/FLSC-C3-AL
4,615,590원
배송: 10 주
 
0.375' Meter, 0.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-104/FLSC-C3-AL
4,615,590원
배송: 10 주
 
0.375' Meter, 0.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-105/FLSC-C3-AL
4,615,590원
배송: 10 주
 
0.625' Meter, 0.75 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-106/FLSC-C3-AL
4,615,590원
배송: 10 주
 
0.625' Meter, 0.75 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-107/FLSC-C3-AL
4,858,070원
배송: 10 주
 
0.75' Meter, 0.75 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-108/FLSC-C3-AL
4,858,070원
배송: 10 주
 
0.75' Meter, 0.75 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-109/FLSC-C3-AL
5,060,840원
배송: 10 주
 
1' Meter, 1 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-110/FLSC-C3-AL
5,060,840원
배송: 9 주
 
1' Meter, 1 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-111/FLSC-C3-AL
5,222,500원
배송: 10 주
 
1.5' Meter, 1.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-112/FLSC-C3-AL
5,222,500원
배송: 10 주
 
1.5' Meter, 1.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-113/FLSC-C3-AL
5,474,900원
배송: 10 주
 
2' Meter, 2 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-114/FLSC-C3-AL
5,474,900원
배송: 10 주
 
2' Meter, 2 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-115/FLSC-C3-AL
7,277,180원
배송: 10 주
 
3' Meter, 3 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
  
SYS/FTBG-116/FLSC-C3-AL
7,277,180원
배송: 10 주
 
3' Meter, 3 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
Accessories
  
FLSC-C3
1,449,200원
배송: 10 주
 
±Replacement 4 to 20 mA signal conditioner for gas turbine system only,
  
FLSC-C3-AL
1,850,490원
배송: 10 주
 
±Replacement 4 to 20 mA signal conditioner with optional high/low alarm for gas turbine system only,
Click to expand/minimize a list of what others bought with theFLSC-C-CABLE
FLSC-C-CABLE
53,740원
배송: 2 주
 
±9-pin D connector to transmitter Molex
Click to expand/minimize a list of what others bought with theOM-CONV-USB
OM-CONV-USB
32,270원
배송: 2 주
 
USB to RS232 converter
모든 가격은 원화로 표시되어 있습니다.
참고: Systems come complete with NIST certificate with K Factor, turbine, signal conditioner in ATEX enclosure, and operator’s manual.

± The purchase of FLSC-C-CABLE and downloadable software (free at FTP.Omega.com) are necessary to program the signal conditioners in the field.

For units with 100 to 240 Vac power, add suffix "-VAC" to model number, add $150 to cost.


We noticed you are from the US. Visit your local site for regional offers and live support.