2 year warranty CE
  • Wide Temperature Range from -20 to 500°C (-4 to 932ºF)
  • Built-In RS485 MODBUS RTU Interface
  • Configurable Emissivity Setting and Signal Processing
  • Max, Min Average and Instantaneous Readings; Peak or Valley Hold; Reflected Energy Compensation
  • 2:1, 15:1, 30:1 or Close Focus Optics
  • Fast Response with High Stability
  • Stainless Steel Housing, Sealed to IP65
  • Quick and Easy Installation
  • Optional Air/Water Cooled Housing, Air Purge Collar, Laser Sighting Tool and Mounting Brackets
  • Optional DP240 Touch-Screen Terminal for Configuring and Displaying Data from Up to 8 IR Sensors
적외선 온도 측정 장비 - 관련 제품 보기

설명

The OS211 Series is a range of high quality, low cost, compact sensors which measure the temperature of inaccessible or moving objects and materials. They measure temperatures from -20 to 500°C (-4 to 935ºF), accurately and consistently, with an outstanding response time of 240 ms. Two-way digital communications via a built-in RS485 MODBUS RTU interface enables the user to adjust the emissivity setting; compensate for reflected energy; apply filtering; select maximum and minimum, average or instantaneous readings; and peak or valley hold processing. Up to 32 sensors can be installed on a single multidrop network. All the IR sensors are fitted with precision germanium lenses for accurate optics. These compact sensors are small enough to fit almost anywhere and their rugged stainless steel housings make them ideal for applications where cleanliness and hygiene are paramount.

The optional DP240 is a 320 x 240 pixel touch screen terminal with a 89 mm (3.5") color TFT display. It allows the user to display data from up to eight infrared sensors and configure each sensor individually. The configuration parameters include emissivity setting, signal averaging, peak or valley hold processing and reflected energy compensation. There are two versions available. Each one provides all of the features above, however, the enhanced DP240-AR also provides analogue transmission for up to 4 sensors, plus two adjustable alarm outputs per sensor for all 8 sensors.

SPECIFICATIONS(OS211)
Temperature Range:
-20 to 500°C (-4 to 932°F)
Interface: RS485 MODBUSR RTU
Accuracy: ±1% of reading or ±1°C whichever is greater
Repeatability: ±0.5% of reading or ±0.5°C whichever is greater
Emissivity: 0.2 to 1.0
Response Time, t90: 240 ms (90% response)
Spectral Range: 8 to 14 µm
Supply Voltage: 12 Vdc nominal (6 to 13 Vdc)
Supply Current: 50 mA max
Baud Rate: 9600 baud*
Format: 8 data bits, no parity, 1 stop bit* Mechanical
Construction: Stainless steel
Dimensions: 18 D x 103 mm L (0.70 x 4.05")
Thread Mounting: m16 x 1 mm pitch
Cable Length: 1 m (3.3') (longer lengths available to order)
Weight with Cable: 95 g (3.35 oz) Environmental
Rating: NEMA (IP65)
Ambient Temperature: 0 to 70°C (32 to 158°F)
Relative Humidity: 95% max non-condensing
*Other configurations available upon request

SPECIFICATIONS(DP240)
Display:
LCD type TFT 320 x 240, 3.5" touch screen resistive
Supply Voltage: 12 to 24 Vdc
Power Consumption: 8 W
Ambient Temperature Range: 0 to 45°C (32 to 113°F)
Relative Humidity: 35 to 95%, non-condensing
Environmental Rating: (IP54) front, (IP30) housing
Dimensions:
    DP240: 140 W x 100 T x 44 mm D
    DP240-AR: 140 W x 100 T x 65 mm D
Outputs: (DP240-AR only) 4 analogue outputs, 0 to 10 Vdc, 16 programmable alarm outputs, 12/24 Vdc, 700 mA, (3 a max per block of 8 outputs)
Hardware and Software Data Serial Port EXP1: RS485 MODBUS RTU interface for infrared sensors
Serial Port COM2: RS485/RS232 interface for second display (read only)
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
  
OS211-C4
판매 상담  
배송: 
 
 
Configurable infrared temperature sensor, 2:1 Optics
  
OS151-C4
판매 상담  
배송: 
 
 
Configurable infrared temperature sensor, 15:1 Optics
  
OS301-C4
판매 상담  
배송: 
 
 
Configurable infrared temperature sensor, 30:1 Optics
  
OS801-C4
판매 상담  
배송: 
 
 
Configurable infrared temperature sensor, Close-focus
  
DP240
판매 상담  
배송: 
 
 
Touch-screen terminal for up to 8 IR sensors from list above
  
DP240-AR
판매 상담  
배송: 
 
 
Touch-screen terminal for up to 8 IR sensors from list above. Includes 4 analog outputs (0 to 10 Vdc) and 16 alarm outputs
Accessories
Click to expand/minimize a list of what others bought with theOS210-FBS
OS210-FBS
33,830원
배송: 2 주
 
Fixed bracket for compact sensors
Click to expand/minimize a list of what others bought with theOS210-ABS
OS210-ABS
76,930원
배송: 2 주
 
Adjustable bracket for compact sensors
  
OS210-APSW
119,060원
배송: 2 주
 
Air purge collar for compact 2:1 sensors
Click to expand/minimize a list of what others bought with theOS210-APSN
OS210-APSN
148,640원
배송: 4 주
 
Air purge collar for compact 15:1, 30:1 and close-focus sensors
Click to expand/minimize a list of what others bought with theOS210-LSTS
OS210-LSTS
705,570원
배송: 4 주
 
Laser sighting tool for compact sensors
Click to expand/minimize a list of what others bought with theCAL-3-IR
CAL-3-IR
판매 상담  
배송: 
 
 
NIST-traceable calibration
Power Supplies
Click to expand/minimize a list of what others bought with thePSR-24S
PSR-24S
판매 상담  
배송: 
 
 
Regulated power supply, US plug, 90 to 264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL
Click to expand/minimize a list of what others bought with thePSR-24L
PSR-24L
판매 상담  
배송: 
 
 
Regulated power supply, US plug, 90 to 264 Vac input, 24 Vdc output, 400 mA, stripped leads, UL
  
PSR-24L-230
143,260원
배송: 2 주
 
Regulated power supply, European plug, 230 Vac input, 24 Vdc output, 400 mA, stripped leads, CE
Click to expand/minimize a list of what others bought with theTX8-100
TX8-100
244,570원
배송: 8 주
 
Power/output cable, 30 m (98')

제품 번호로 주문하기

제품 번호
수량
제품 번호
수량


모든 가격은 원화로 표시되어 있습니다.
참고: Add -WC for air/water cooled jacket, add suffix to model number (includes air purge collar), must be ordered with sensor; cannot be retrofitted
Add -CE(*) 4 Cable extended, for uncooled IR USB series, 30 m (98') max total cable length
Add -CEHT(*) 13 Cable extended, high temperature, for cooled IR USB series, 30 m (98') max total cable length
* 1 m (3.3') cable is included as standard on every sensor. Extended cable is added to that length, add suffix to model number. Insert cable length in meters

Comes complete with sensor head, 1 m (3.3') cable, USB cable, software, and operator's manual.
We noticed you are from the US. Visit your local site for regional offers and live support.