Transient Pressure Data Logger, Part of the Nomad® Family

OM-CP-PRTRANS Series

Transient Pressure Data Loggerm Part of the Nomad® Family | OM-CP-PRTRANS Series

Transient Pressure Data Loggerm Part of the Nomad® Family

페이지 하단에서 가격을 확인하세요.

5 year warranty
  • 100 Hz Operation
  • Software Selectable Trigger
  • Rugged
  • Submersible
  • Programmable Start Time
  • 32 Sample Pre-Trigger Buffer
  • Ready to Use Right Out-of-the-Box
  • Free NIST Certification
압력 트렌스듀서 - 관련 제품 보기

설명

It is an all too common paradox: you need to capture transient events at a high sample rate, but the events of interest are erratically spread over a long period. The OM-CP-PRTRANS pressure recorder can solve your problems. It samples up to 100 Hz (10 ms) but it will only trigger on pressure limits that you set beforehand. You can start the trigger on high or low thresholds and end the trigger after either a chosen number of samples, or when the signal crosses over your stop threshold. The device can record up to 255 events and take as many as 262,143 pressure samples. It also shows up to 32 samples of "pre-trigger" data so that you can learn what caused the trigger in the first place.

The OM-CP-PRTRANS is a battery operated unit with a standard 1/4 NPT for easy coupling to your pressure systems. It is also completely submersible and the stainless steel sensor can measure the pressure of most common fluids and gases. The non-volatile memory will retain valuable data even if the user-replaceable battery becomes discharged. The OM-CP-PRTRANS is your solution to the transient pressure problem.

SPECIFICATIONS
Pressure Sensor:
Semiconductor strain gauge
Calibrated Accuracy: 2% FSR, 0.25% @ 25°C typical
Pressure Response Time: 0.1 ms (10 to 90% FSR)
Repeatability: ±0.5% FSR; ±0.2% typical
Adaptor: 1/4" male NPT or fully submersible
Trigger Modes: Software programmable window size of bi-level start/stop triggers
Start Time: Software programmable immediate start time or delay start up to 7 days in advance
Real Time Recording: May be used with PC to monitor and record data in real time
Memory: Up to 262,143 samples
Number of Events: Up to 255 triggered events
Pre-Trigger Size: Up to 32 samples
Recording Interval: 1 reading every 10 ms to 1 every second
Calibration: Digital calibration is available through software
Calibration Date: Automatically recorded within device
Power: 3.6 V lithium battery (included)
Battery Life: 3 days continuous @ 10 ms sample rate
Shelf Life: Up to 1 year when not in use
Data Format: Date and time stamped, psia, psag, inches, feet, mmHg, bar, torr, kPa
Computer Interface: PC serial or USB (interface cable required) 115,200 baud
Software: XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -40 to 80°C (-40 to 176°F) 0 to 100% RH non-condensing
Dimensions: 163 mm x 32 mm L (6.4 x 1.25")
Weight: 340 g (12 oz)
Material: Stainless steel
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
Transient Pressure Data Loggers with 1/4 NPT Fitting, Absolute Ranges
  
OM-CP-PRTRANS-1-30A
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-30 psia range
  
OM-CP-PRTRANS-1-100A
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-100 psia range
  
OM-CP-PRTRANS-1-300A
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-300 psia range
  
OM-CP-PRTRANS-1-500A
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-500 psia range
  
OM-CP-PRTRANS-1-1000A
판매 상담  
배송: 
 
 
Transient pressure data logger, 1-1000 psia range
Click to expand/minimize a list of what others bought with theOM-CP-PRTRANS-1-5000A
OM-CP-PRTRANS-1-5000A
판매 상담  
배송: 
 
 
Transient pressure data logger, 1-5000 psia range
Transient Pressure Data Loggers with 1/4 NPT Fitting, Gage Ranges
  
OM-CP-PRTRANS-1-30G
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-30 psig range
  
OM-CP-PRTRANS-1-100G
판매 상담  
배송: 
 
 
Transient pressure data logger, 1-100 psig range
Click to expand/minimize a list of what others bought with theOM-CP-PRTRANS-1-300G
OM-CP-PRTRANS-1-300G
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-300 psig range
Click to expand/minimize a list of what others bought with theOM-CP-PRTRANS-1-500G
OM-CP-PRTRANS-1-500G
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-500 psig range
Fully Submersible Transient Pressure Data Loggers, Absolute Ranges
  
OM-CP-PRTRANS-0-30A
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-30 psia range
  
OM-CP-PRTRANS-0-100A
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-100 psia range
Fully Submersible Transient Pressure Data Loggers, Gage Ranges
  
OM-CP-PRTRANS-0-30G
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-30 psig range
  
OM-CP-PRTRANS-0-100G
판매 상담  
배송: 
 
 
Transient pressure data logger, 0-100 psig range
Accessories
Click to expand/minimize a list of what others bought with theOM-CP-IFC200
OM-CP-IFC200
264,480원
배송: 2 주
 
Windows software and 1.8 m (6') USB interface cable
  
OM-CP-SVP-SYSTEM
3,220,120원
배송: 3 주
 
FDA 21 CFR part 11 compliant IQ/OQ/PQ secure software validation workbook and software package (unlimited users, license per computer)
모든 가격은 원화로 표시되어 있습니다.
참고: Operator's manual and USB interface cable are included with the OM-CP-IFC200 Windows software (software sold separately). Fully submersible data loggers are only available in 0-30 psia, 0-30 psig, 0-100 psia and 0-100 psig ranges

This product page contains items that either have a Lithium Battery installed in the equipment or have a Lithium Battery packed with the equipment. These items as being regulated for air transportation. The following applies:
• No FX1D, FX2D or FX3D can be used as a ship method.
• Only UPS1, UPS2 or UPS3 is authorized.
• For International shipments UPS and DHL can be used. For DHL internationally – Omega only has permission to ship Lithium Batteries no other Hazardous Material.

소프트웨어:

다운로드 OM-CP Data Logging Software
다운로드 OM-CP software
We noticed you are from the US. Visit your local site for regional offers and live support.