장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나은행 201-910031-70804

[단종] Event Data loggers
Part of the NOMAD® Family

OM-CP-EVENT101 & OM-CP-EVENT110

단종 - Event Data Loggers | OM-CP-EVENT101 & OM-CP-EVENT110

단종 - Event Data Loggers

페이지 하단에서 가격을 확인하세요.

1 year warranty CE
  • Memory: 13,107 Time Stamped Events
  • Miniature Size
  • Memory Wraparound
  • Interfaces to Tipping Bucket Rain Gages and Other Devices with TTL Pulse, Contact Closure Output
  • Real-Time Operation
  • Operational in Minutes

설명


이 제품은 단종되었습니다. 대체품으로 OM-CP-EVENT101A를 확인 요청드립니다.
문의사항이 있으시면, 영업 담당자에게 문의하여 주십시오.


The OM-CP-EVENT101 and OM-CP-EVENT110 are low-cost recording devices that will sense a contact closure from external sources such as transducers or pulse initiators (gas, water, and electric meters) and record the time that a particular event has occurred. Once activated the data logger senses and records transition or state changes at the input. Its real time clock ensures that all data is time and date stamped. This is ideal for recording events. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. Its small size allows it to fit almost anywhere. Data retrieval is simple. Plug it into an available COM port and our easy-to-use software does the rest. The software converts your computer into a real time strip chart recorder. Data can be printed in graphical or tabular format and can be exported to a text or Microsoft Excel file.

Specifications
Event Resolution: 1 second (records only up to 1 event per second,
works with flow meters that output less than one pulse/second)
Minimum Contact Closure Time: 1 msec
Input Range: 0 to 12 Vdc continuous; (0 to 30 Vdc peak)
Input Low: <0.4V
Input High: >2.7V
Internal Weak Pull-Up: < 500µa
Recommended Duty Cycle for Inputs Greater Than 12 Vdc (Over 1 min Interval @ 25°C): 18V:<50%; 24V:<25%; 30V:<10%
Event Recording: Device records an event when the contact closes
(falling edge of the electrical signal)
Input Connection: Removable screw terminal
Input Impedance: >1 KΩ
Memory Wrap Around: Selectable in software
Real Time Recording: Device may be used with PC
to monitor and record data in real time
Visual Indicator: LED flashes on event
Power: 3.6 V lithium battery included
Battery Life: OM-CP-EVENT101: 1 year at 25°C
OM-CP-EVENT110: 10 years at 25°C
Time Accuracy: ±1 minute per month at 20°C (68°F)
when RS-232 is not in use
Data Format: Date and time stamped
Computer Interface: PC serial, RS-232C COM or USB
(interface cable required)
Communications: OM-CP-EVENT101: 2400 baud
OM-CP-EVENT110: 57600 baud
Software:XP SP3/Vista and 7 (32 and 64-bit)
Operating Environment: -40 to 80°C (-40 to 176°F)
0 to 95% RH non-condensing
Dimensions: OM-CP-EVENT101: 36 H x 64 W x 16 mm D (1.4 x 2.5 x 0.6")
OM-CP-EVENT110: 43 H x 69 W x 20 mm D (1.7 x 2.7 x 0.8")
Weight: OM-CP-EVENT101: 30 g (1 oz)
OM-CP-EVENT110: 60 g (2 oz)
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
Click to expand/minimize a list of what others bought with theOM-CP-EVENT101
OM-CP-EVENT101
판매 상담  
배송: 
 
 
[단종] Event data logger with 1-year battery life (CE approved only)
  
OM-CP-EVENT110
판매 상담  
배송: 
 
 
[단종] Event data logger with 10-year battery life
Click to expand/minimize a list of what others bought with theOM-CP-IFC200
OM-CP-IFC200
264,480원
배송: 2 주
 
[단종] Windows software and 3.7 m (12') USB interface cable
모든 가격은 원화로 표시되어 있습니다.
참고: Comes complete with 3.6V lithium battery. Operator’s manual and interface cable are included with the OM-CP-IFC200 software/cable package (required for data logger operation, sold separately). OM-CP-EVENT101 is CE approved only.

제품 메뉴얼:

다운로드 OM-CP Series - Data Logger and Software User Guide
다운로드 OM-CP Series - Data Logger Quickstart Guide
We noticed you are from the US. Visit your local site for regional offers and live support.