ULTRASONIC LEVEL CONTROLLER

LVCN1700 Series

Ultrasonic Level Switch | LVCN1700 Series

Ultrasonic Level Switch

1,666,020원 LVCN1710

1 year warranty
  • Offered in 3 Ranges From 3 to 8 m (9.8 to 26.2')
  • Configuration is Simple Via Integral Pushbutton Display Module
  • Three Programmable Relays for Switch, Pump Control and Fail-Safety
  • LCD Display Indicates Level Height and Relay Status
  • Narrow 5 or 7.6 cm (2 or 3") Beam Width and Short 4" or 8" Dead Band
  • PVDF Transducer and NEMA 4X (IP65) Poly-Carbonate Enclosure
  • Automatic Temperature Compensation for Accurate Measurement
레벨 측정 - 관련 제품 보기

설명

OMEGA’s LVCN1700 ultrasonic level sensor provides level detection up to 8 m (26.2') with 3 programmable relays for level switch or level control functions, and is configured via the integral pushbutton display module. Each relay can be configured on a single set-point (high level alarm or low level alarm) or latched on two set points for automatic fill or empty in simplex (one pump or valve), duplex (two pumps) or triplex (three pumps) level control modes with selectable time delay and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is broadly selected for pump lift station, sump and day tank level applications

Specifications
Range:
    LVCN1710: 10 cm to 3 m (4" to 9.8')
    LVCN1718: 20 cm to 5.5 m (8" to 18')
    LVCN1726: 20 cm to 8 m (8" to 26.2')
Repeatability: 6.35 mm (0.25")
Dead Band:
    LVCN1710: 10 cm (4")
    LVCN1718/26: 20 cm (8")
Beam Width:
    LVCN1710: 5 cm (2")
    LVCN1718/26: 7.6 cm (3")
Configuration: Pushbutton
Memory: Non-volatile
Display Type: LCD, 6-digit
Display Units: Inch, cm, percent, feet or meter
LCD Indication: Level and relay status
Supply Voltage: 95 to 250 Vac
Power: 20 W @ 120 Vac
Contact Type: (3) SPDT relays
Contact Rating: 60 VA, 1A max
Contact Fail-Safe: Open, close or hold last
Process Temp: -20 to 60°C (-7 to 140°F)
Temp Comp: Automatic
Ambient Temp: -40 to 71°C (-40 to 160°F)
Pressure: Maximum Working Pressure = 30 psi (2 bar)
Enclosure
    Rating: NEMA 4X (IP65)
    Material: Polycarbonate
    Hardware: Brass and stainless
    Vent: Water tight membrane
Trans Material: PVDF
Conduit Entrance: Dual, ½ NPT
Process Mount:
    LVCN1710: 1 NPT (1" G optional)
    LVCN1718/26: 2 NPT (2" G optional)
Mount Gasket: FKM
Classification: General purpose
Compliance: RoHS
가격 확인(원하는 수량을 기입하십시오.)
제품 번호/Desc.
수량
설명
LVCN1710
1,666,020원
배송: 2 주
 
Ultrasonic level controller 3 SPDT relays, range 3 m (9.8')
LVCN1718
1,727,880원
배송: 10 주
 
Ultrasonic level controller 3 SPDT relays, range 5.5 m (18')
LVCN1726
1,825,620원
배송: 10 주
 
Ultrasonic level controller 3 SPDT relays, range 8 m (26.2')
모든 가격은 원화로 표시되어 있습니다.
참고: Comes complete with mounting gasket and operator’s manual.