장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나 은행 455-910025-42804

Compact Enclosure Fan Heater

HVL031 Series

DIN Rail Enclosure Heater | HVL031 Series

DIN Rail Enclosure Heater

198,900원 HVL03900

1 year warranty CE
  • Small, Compact Size Fan Heater
  • Built-In Overheat Protection
  • DIN Rail Mountable
  • Maintains Minimum Operating Temperatures in Enclosures
  • Helps to Prevent Failure of Electronic Components Caused by Condensation and Corrosion

설명

This compact heater is designed for many different applications including electrical and electronic enclosures, display panels, access and parking control systems and personnel booths.

To determine the required heater size follow this equation:

PH = (A x ΔT x k) - Pv
PH = Required heating power for your application in Watts (W)
Pv = Heating power generated by existing components (e.g. a transformer) in Watts (W)
A = Exposed enclosure surface area square meters (m2)
ΔT = Temperature differential between the desired minimum interior temperature and lowest possible external temperature of the enclosure in Kelvin (K), 1.8°F = 1°C = 1K
k = Heat transmission coefficient of the enclosure material used:
    Stainless Steel: 3.7 W/m2K
    Painted Steel: 5.5 W/m2K
    Aluminum: 12 W/m2K
    Polyester/Plastic: 3.5 W/m2K

For outdoor applications it is recommended to double the heating power.

SPECIFICATIONS
Operating Voltage: 120 Vac
Wattage:
    HVL02900: 100 W
    HVL03900: 150 W
    HVL13900: 200 W
    HVL14900: 300 W
    HVL15900: 400 W
Heating Element: Resistance type cartridge heater
Heat Sink: Die-cast aluminum, glass bead finish
Required Fan Size (Included):
    100/150 W: 80 x 80 x 25 mm (3.1 x 3.1 x 0.98")
    Min Air Flow: 35 m3/h (115 ft3/h) (20 cfm)
    200/300/400 W: 120 x 120 x 25 mm (4.7 x 4.7 x 0.98")
Min Air Flow: 108 m3/h (354 ft3/h) (63 cfm)
Overheat Protection: Built-in temperature limiter
Air Exit Temperature: Approx. 45°C (113°F) 50 mm (2") above heater
Wiring Compartment: Plastic UL 94V-O
Connection (Heater): 3-pole terminal, AWG 14 max [2.5 mm2 (0.10 in2)]
Connection (Axial Fan): 2-pole terminal (L2/N2), AWG 14 max [2.5 mm2 (0.10 in2)]
Mounting: Clip for 35 mm (1.4") DIN rail (EN 50022)
Protection Class: I (grounded)
Protection Type: NEMA 2 (IP20)
Weight (with Fan):
    100/150 W: 600 g (1.3 lb)
    200/300/400 W: 900 g (2.0 lb)
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
Quick Ship
Click to expand/minimize a list of what others bought with theHVL02900
HVL02900
193,370원
배송: 2 주
 
Fan heater, 100 W, 120 Vac
Quick Ship
Click to expand/minimize a list of what others bought with theHVL03900
HVL03900
198,900원
배송: 2 주
 
Fan heater, 150 W, 120 Vac
Quick Ship
Click to expand/minimize a list of what others bought with theHVL13900
HVL13900
221,000원
배송: 2 주
 
Fan heater, 200 W, 120 Vac
Quick Ship
Click to expand/minimize a list of what others bought with theHVL14900
HVL14900
218,240원
배송: 8 주
 
Fan heater, 300 W, 120 Vac
Quick Ship
Click to expand/minimize a list of what others bought with theHVL15900
HVL15900
225,140원
배송: 2 주
 
Fan heater, 400 W, 120 Vac
모든 가격은 원화로 표시되어 있습니다.
참고: Comes with complete operator’s manual, mounting kit and axial fan.
주문 예: (1) HVL02900 Fan heater, 100 W, 193,370원