장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나은행 201-910031-70804

Compact Enclosure Fan Heater

HVL031 Series

DIN Rail Enclosure Heater | HVL031 Series

DIN Rail Enclosure Heater

342,200원 HVL03900

1 year warranty CE
  • Small, Compact Size Fan Heater
  • Built-In Overheat Protection
  • DIN Rail Mountable
  • Maintains Minimum Operating Temperatures in Enclosures
  • Helps to Prevent Failure of Electronic Components Caused by Condensation and Corrosion

설명

This compact heater is designed for many different applications including electrical and electronic enclosures, display panels, access and parking control systems and personnel booths.

To determine the required heater size follow this equation:

PH = (A x ΔT x k) - Pv
PH = Required heating power for your application in Watts (W)
Pv = Heating power generated by existing components (e.g. a transformer) in Watts (W)
A = Exposed enclosure surface area square meters (m2)
ΔT = Temperature differential between the desired minimum interior temperature and lowest possible external temperature of the enclosure in Kelvin (K), 1.8°F = 1°C = 1K
k = Heat transmission coefficient of the enclosure material used:
    Stainless Steel: 3.7 W/m2K
    Painted Steel: 5.5 W/m2K
    Aluminum: 12 W/m2K
    Polyester/Plastic: 3.5 W/m2K

For outdoor applications it is recommended to double the heating power.

SPECIFICATIONS
Operating Voltage: 120 Vac
Wattage:
    HVL02900: 100 W
    HVL03900: 150 W
    HVL13900: 200 W
    HVL14900: 300 W
    HVL15900: 400 W
Heating Element: Resistance type cartridge heater
Heat Sink: Die-cast aluminum, glass bead finish
Required Fan Size (Included):
    100/150 W: 80 x 80 x 25 mm (3.1 x 3.1 x 0.98")
    Min Air Flow: 35 m3/h (115 ft3/h) (20 cfm)
    200/300/400 W: 120 x 120 x 25 mm (4.7 x 4.7 x 0.98")
Min Air Flow: 108 m3/h (354 ft3/h) (63 cfm)
Overheat Protection: Built-in temperature limiter
Air Exit Temperature: Approx. 45°C (113°F) 50 mm (2") above heater
Wiring Compartment: Plastic UL 94V-O
Connection (Heater): 3-pole terminal, AWG 14 max [2.5 mm2 (0.10 in2)]
Connection (Axial Fan): 2-pole terminal (L2/N2), AWG 14 max [2.5 mm2 (0.10 in2)]
Mounting: Clip for 35 mm (1.4") DIN rail (EN 50022)
Protection Class: I (grounded)
Protection Type: NEMA 2 (IP20)
Weight (with Fan):
    100/150 W: 600 g (1.3 lb)
    200/300/400 W: 900 g (2.0 lb)
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
  
HVL02900
349,060원
배송: 12 주
 
Fan heater, 100 W, 120 Vac
  
HVL03900
342,200원
배송: 2 주
 
Fan heater, 150 W, 120 Vac
  
HVL13900
386,760원
배송: 2 주
 
Fan heater, 200 W, 120 Vac
  
HVL14900
374,920원
배송: 2 주
 
Fan heater, 300 W, 120 Vac
Click to expand/minimize a list of what others bought with theHVL15900
HVL15900
344,960원
배송: 6 주
 
Fan heater, 400 W, 120 Vac
모든 가격은 원화로 표시되어 있습니다.
참고: Comes with complete operator’s manual, mounting kit and axial fan.
주문 예: (1) HVL02900 Fan heater, 100 W, 349,060원
We noticed you are from the US. Visit your local site for regional offers and live support.