장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나은행 201-910031-70804

Thermal Dispersion Flow Switches

FSW-6000 and FSW-7000 Series

Thermal Dispersion Flow Switches | FSW-6000 and FSW-7000 Series

Thermal Dispersion Flow Switches

1,366,860원 FSW-6212

1 year warranty
  • Simple to Install and Low Cost
  • No Moving Parts-Maintenance Free Reliability
  • Optimal Temperature Compensation — Unaffected by Temperature Gradient
  • Can Operate in Temperatures up to 120°C (248°F) with Sanitary Option
  • Have a Maximum Working Pressure of 4,300 PSI (300 bar)
  • Chain of 8 LEDs- Integrated Flow Rate/Setpoint Indication
  • Can Be Used as a Level Switch
가변 변적 유량계, 액체 유량 미터 / 앰프; 스위치 - 관련 제품 보기

설명

The FSW-6000/7000 Series are thermal flow switch monitors designed to monitor flow status and also used to detect level of liquids, air and gas. A chain of 8 LED’s gives the user a visual indication of the flow rate. In addition, there isalso a dichromatic LED, which shows the switch point status of the unit. The sensing element and connection of the FSW-6000/7000 Series are made with 316 SS. The standard enclosure is glass-filled nylon and is also available in an aluminum enclosure for hazardous environments. The FSW-6000/7000 Series can be made with a great variety of process connections such as threaded, flange, or sanitary.

The FSW-6000/7000 Series line of thermal flow switch monitors is based on the principle of thermal dispersion. A typical configuration uses two platinum Resistance Temperature Detectors (RTD’s) set within the tip of the sensor. One RTD is heated a few degrees above the temperature of the medium and the other RTD is used as a reference, sensing the actual process temperature. The second RTD also monitors the temperature of the medium, as any changes in temperature must be compensated for in the first RTD. As the process medium flows over the tip of the sensor it disperses some of theheat from the first RTD. The temperature change between the two RTD's signals the probe’s electronics and the switch changes state once the set point has reached.

The FSW-6000/7000 Series may be installed in a pipe or tank using the thread or connection provided. Use only the hexagon when tightening to achieve a seal, do not use the body. The body should be rotated after tightening to leave the cable gland in suitable orientation. The FSW-6000/7000 Series is not affected by its fixing position so it may be installed at any angle around the pipe. However, it is recommended that with horizontal pipe runs the sensor should be installed on the side, into the middle of the pipe. In vertical pipes, the FSW-6000/7000 Series should be installed when there is flow in an upward direction against gravity. Care should be taken when installing the sensor that the probe extends clear of the pipe’s internal wall and is fully immersed into the flow. In pipes with smaller diameters, some care should also be taken so that the sensor is not screwed too far into the line.

SPECIFICATIONS
Accuracy: ±10% of setpoint
Repeatability: ±1% of setpoint
Power Supply:
    FSW-6000: 85 to 240 Vac (50/60 Hz)
    FSW-7000: 24 Vdc ±10%
Temperature Range:
    Process: -20 to 80°C (-4 to 176°F) [sanitary option to 120°C (248°F) for CIP]
    Operating: -20 to 60°C (-4 to 140°F)
Max Pressure: 300 bar (4351 psi)
Protection Class: NEMA 4 (IP65)
Wetted Materials: 316 SS
Enclosure Material: Glass filled nylon standard or aluminum die cast option
Process Connection: ½ to 1½ NPT, Tri-Grip™, or flange (others available, consult Flow Engineering Department)
Output: 250 Vac SPDT 5 A relay
Switch Point Adjustment: Potentiometer
Bargraph:
    Green LED: Flow rate above setpoint
    Yellow LED: Flow is at above setpoint
    Red LED: Flow is below setpoint
Switch Point Status:
    Red LED: No flow
    Green LED: Flow
Response Time: 1 to 10 seconds
Max Start up Delay: 12 seconds
Switching Range: 3 cm/s to 3 m/s (0.09 to 9.84 ft/sec) (liquid), 5 cm/sec to 15 m/sec (0.16 to 49 ft/sec) (gas)
Dimensions:
    Nylon Head: 88 Dia x 80 mm H (3.5 x 2.5" H)
    Aluminum Head: 88 Dia x 108 mm H (3.5 x 4.25")
    Insertion Length: 138, 2 and 3" standard, for other lengths consult Flow Engineering
     Maximum insertion Length is 36"

    Weight: Approx 680 g (1.5 lb)
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
  
FSW-6212
1,366,860원
배송: 8 주
 
85 to 240 Vac, 3/4 NPT, 2" length, glass filled nylon with 1/2 NPT conduit, cable gland, and 2 m (6.5') cable. For 1" to 4" pipes
  
FSW-6222
1,288,820원
배송: 8 주
 
85 to 240 Vac, 3/4 NPT, 2" length aluminum die cast with 1/2 NPT conduit, and 2 m (6.5') cable. For 1" to 4" pipes
  
FSW-6512
1,496,910원
배송: 8 주
 
85 to 240 Vac, 1-1/2 Tri-Grip™, 2" length, glass filled nylon with 1/2 NPT conduit with cable gland, and 2M (6.5') cable. For 1 to 4" pipes
  
FSW-7111
1,366,860원
배송: 8 주
 
24 Vdc, 1/2 NPT, 35 mm (1 3/8") length, glass filled nylon with 1/2 NPT conduit with cable gland, 2m (6.5') cable. For pipes up to 1"
  
FSW-7112
1,130,380원
배송: 8 주
 
24 Vdc, 1/2 NPT, 50 mm (2") length, glass filled nylon with 1/2 NPT conduit with cable gland, 2m (6.5') cable. For 1" to 4" pipes
  
FSW-7121
1,288,820원
배송: 8 주
 
24 Vdc, 1/2 NPT, 35 mm (1-3/8") length, aluminum die cast with 1/2 NPT conduit, 2 m (6.5') cable. For 1" to 4" pipes
  
FSW-7122
1,417,700원
배송: 8 주
 
24 Vdc, 1/2 NPT, 50 mm (2") length, aluminum die cast with 1/2 NPT conduit, 2 m (6.5') cable. For 1" to 4" pipes
Accessories
Click to expand/minimize a list of what others bought with the70A-1
70A-1
66,820원
배송: 2 주
 
Continuous tone alarm
Click to expand/minimize a list of what others bought with theTX4-100
TX4-100
79,800원
배송: 2 주
 
30.5 m (100') spool of 4 Conductor Wire
Click to expand/minimize a list of what others bought with theU24Y175
U24Y175
판매 상담  
배송: 
 
 
24 Vdc power supply
모든 가격은 원화로 표시되어 있습니다.
참고: Comes complete with operator’s manual.

For "ECTFE/ETFE" element coating, add suffix "-ETFE" to model number, add $200 to price.


주문 예: (1) FSW-6212 Flow Switch, 1,366,860원

제품 번호 생성기

제품 옵션을 선택하세요
옵션 선택:


(1) Power 선택하기:
6 : 85 to 240 Vac
7 : 24 Vdc ± 10%

(2) Process Connection 선택하기:
1 : 1/2 NPT thread
2 : 3/4 NPT thread
3 : 1 NPT thread
5 : 1-1/2" Tri-Grip
6 : 2" ANSI flange

(3) Enclosure 선택하기:
1 : Glass filled nylon with 1/2 NPT conduit and cable gland
2 : Aluminum die cast with 1/2 NPT conduit
3 : Aluminum die cast with cable gland

(4) Insertion Length 선택하기:
1 : 35 mm (1-3/8")
2 : 50 mm (2")
3 : 75 mm (3")
참고: 제품 구성 시 ‘판매 상담’으로 표시되어있는 제품은 영업부와 상담하십시오.