장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나은행 201-910031-70804

Coriolis Mass Flow Meter

FMC-5000

Coriolis Flow Meters | Mass Flow Meters | OMEGA | FMC-5000

Coriolis Flow Meters | Mass Flow Meters | OMEGA

페이지 하단에서 가격을 확인하세요.

2 year warranty CE
  • Mass Flow Rate, Volume, Density and Temperature Measurements
  • Rugged Meters with No Moving Parts Results in Minimal Maintenance
  • Accuracy Over a Wide Flow Range From a Single Meter Optimizes Plant Efficiency
  • No Flow Conditioning or Straight Pipe Runs Required, Making Installation Simplified and Less Expensive
전자식 질량 유량계 - 관련 제품 보기

설명

The FMC-5000 Coriolis Mass Flow Meter is designed according to the Coriolis Force Principle. It is widely used for flow measurements and custody transfer in many industries such as petroleum, petrochemical, chemical, pharmaceutical, pulp and paper, food and dairy, and more. As an advanced flow and density measurement instrument, it is widely used in the measurement of liquids, gases and slurries, and garners a high reputation among customers around the globe. Coriolis meters are typically used in applications like batch control, blending, filling, dosing, custody transfer, process gas measurements, and more.

The FMC-5000 Series Coriolis Meter is designed according to the principle of Coriolis force. Under the alternating current effect, the electromagnetic coils mounted on the measuring tube will make two parallel measuring tubes vibrating at a certain fixed frequency. Whenever mass (either liquid or gas) flows through the measuring tubes, Coriolis force is generated, causing a “bending” or “deflection” in the top of the tubes. This deflection is sensed as a phase shift between two electronic pick-ups mounted on the tubes. The degree of phase shift is directly proportional to the mass flow within the tubes. The mass flow rate can be calculated by detecting the phase shift of the tubes. The temperature is also measured and used for compensation.



Specifications
Flow Range: See charts below
Connection: ANSI, DIN, JIS, or Sanitary Tri-Clamp flanges
Maximum Pressure: 16 bar (230 psi), [Optional: 25 bar (360 psi), 40 bar (580 psi) and 63 bar (913.7 psi)]
Body Material: 304 Stainless Steel
Measuring Tube Material: 316 L SS
Process Temperature Range:
    Integrate Type: -50 to 125°C (-58 to 257°F)
    Remote Type (-R): -50 to 200°C (-58 to 392°F)
Ambient Temperature: -40 to 55°C (-40 to 131°F)
Working Humidity: (5 to 95%) RH at 25°C (77°F)
Flow Accuracy/Repeatability:
    FMC-5100: 0.1/0.05% (Liquid Only)
    FMC-5200: 0.2/0.1% (Liquid Only)
    FMC-5500: 0.5/0.25%
Density Measuring:
    Range: 0.2 to 3.0 g/cm3
    Error: ± 0.002 g/cm3
    Repeatability: 0.001 g/cm3
Temperature Accuracy: ±1.0°C
Protection: NEMA 4X (IP65)
Approvals: CE, RoHS
Communications: RS485 (RTU Modbus®), HART® (-HART option)
Pulse Output: 0 to 10 kHz, ± 0.075% Full Scale
Current Output: 4 to 20 mA, 0.005% Full Scale
Power Supply: 18 to 36 Vdc, 85 to 265 Vac (-AC option), 15 W
가격 확인(원하는 수량을 기입하십시오.)
제품 번호/Desc.
수량
설명
Compact Liquid Coriolis Meters with 0.5% Accuracy
FMC-5501LA
8,365,080원
배송: 5 주
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5502LA
9,804,450원
배송: 2 주
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5503LA
11,026,270원
배송: 5 주
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5504LA
14,160,420원
배송: 15 주
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5505LA
18,588,890원
배송: 16 주
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5506LA
29,829,580원
배송: 16 주
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5507LA
38,175,740원
배송: 16 주
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
Compact Liquid Coriolis Meters with 0.2% Accuracy
FMC-5201LA
10,023,590원
배송: 10 주
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5202LA
11,464,550원
배송: 10 주
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5203LA
12,812,480원
배송: 10 주
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5204LA
17,130,610원
배송: 10 주
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5205LA
22,834,500원
배송: 16 주
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5206LA
35,460,950원
배송: 16 주
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5207LA
46,230,230원
배송: 16 주
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
Compact Liquid Coriolis Meters with 0.1% Accuracy
FMC-5101LA
12,829,830원
배송: 14 주
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5102LA
13,487,240원
배송: 10 주
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5103LA
15,364,880원
배송: 10 주
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5104LA
19,681,430원
배송: 10 주
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5105LA
24,400,000원
배송: 16 주
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5106LA
42,586,870원
배송: 16 주
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5107LA
54,920,080원
배송: 16 주
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
Air/Gas
FMC-5501GA
8,365,080원
배송: 10 주
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5502GA
9,804,450원
배송: 10 주
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5503GA
11,026,270원
배송: 10 주
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5504GA
14,160,420원
배송: 10 주
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5505GA
18,588,890원
배송: 16 주
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5506GA
29,829,580원
배송: 16 주
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5507GA
38,175,740원
배송: 16 주
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
모든 가격은 원화로 표시되어 있습니다.
참고: Comes complete with operator’s manual.
NOTE: HEAVY WEIGHT - NO UPS - MOTOR FREIGHT ONLY!!! OVERWEIGHT SHIPPING CHARGES WILL APPLY FOR THIS PRODUCT. IF ORDERED ON-LINE INTERNET SALES WILL CONTACT YOU AFTER ORDER PLACEMENT UNLESS YOU OPT TO CHARGE FREIGHT TO YOUR CARRIER ACCOUNT.
For meters with other than ANSI flanges, change the “A” at the end of the model number to “D” for DIN flanges, “J” for JIS flanges or “S” for Sanitary Tri-Clamp flanges (liquid only),
no additional charge.
To replace the RS485 communications with HART communications add “-HART” to the model number,
for an additional charge.
For units with remote mounted display/transmitter add “-R” to the model number, for an additional charge.

제품 번호 생성기

제품 옵션을 선택하세요
옵션 선택:


(1) Accuracy 선택하기:
1 : 0.1%
2 : 0.2%
5 : 0.5%

(2) Size Mounting 선택하기:
1 : 1/2" (15 mm)
2 : 1" (25 mm)
3 : 1 1/2" (40 mm)
4 : 2" (50 mm)
5 : 3" (80 mm)
6 : 4" (100 mm)
7 : 6" (150 mm)

(3) Media Type 선택하기:
G : Gas (0.5% Accuracy Only)
L : Liquid

(4) Flange Type 선택하기:
A : ANSI
D : DIN
J : JIS
S : Sanitary (Liquid Only)

(5) Remote Display Option 선택하기:
없음(공란으로 비워두기) : None
-R : Remote Mounted Display/Transmitter

(6) HART Communications Option 선택하기:
없음(공란으로 비워두기) : RS485 Communications
-HART : HART Communications
참고: 제품 구성 시 ‘판매 상담’으로 표시되어있는 제품은 영업부와 상담하십시오.

제품 메뉴얼:

다운로드 Quick - Start Mass Flowmeter Manual
다운로드 Coriolis Mass Flowmeters
We noticed you are from the US. Visit your local site for regional offers and live support.