  • Bi-Directional Flow/Energy Measurement
  • Rugged, Aluminum Enclosure
  • Rate and Total Backlit Display
  • 4 to 20 mA and Dual Alarm Outputs
  • USB Programming Port
  • RS485 MODBUS® Network Connection

설명

Discontinued, no replacement.

.
FDT-40E Series ultrasonic flow and energy meters clamp on to the outside of pipes and do not come in contact with the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates. FDT-40E Series is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.

Specifications
System
Liquid Types: Most clean liquids or liquids containing small amounts of suspended solids or gas bubbles
Velocity Range: Bi-directional to greater than 40 FPS (12 MPS)
Flow Accuracy:
    Larger Than 50 mm (2"): ±1% of reading or ±0.01 FPS (0.003 MPS), whichever is greater
    25 to 50 mm (1 to 2"): ±1% of reading or ±0.04 FPS (0.012 MPS), whichever is greater
    19 mm (¾") and Smaller: ±1% of full scale
Temperature Accuracy:
    Absolute: 0.25°C (0.45°F)
    Difference: 0.1°C (0.18°F)
Energy Temperature Range: 0 to 100°C (32 to 212°F)
Sensitivity Flow: 0.001 FPS (0.0003 MPS)
Temperature: 0.025°C (0.05°F)
Repeatability: 0.5% of reading Transmitter
Power Requirements (AC): 95 to 264 Vac 47 to 63 Hz @ 17 VA maximum standard, 20 to 28 Vac 47 to 63 Hz @ 0.35 A maximum (“-24VAC” models), 10 to 28 Vdc @ 5 W maximum (“-VDC” models)
Protection: Auto resettable fuse, reverse polarity and transient suppression
Display: Two line LCD, LED backlit; top row 18 mm (0.7") height, 7-segment; bottom row 9 mm (0.35") height, 14-segment
Icons: RUN, PROGRAM, RELAY1, RELAY2
Flow Rate Indication: 8-digit positive, 7-digit negative maximum; auto decimal, lead zero blanking
Flow Totalizer: 8-digit positive, 7-digit negative maximum (re-set via keypad press, software, network command or momentary contact closure
Enclosure NEMA 4 (IP65) Construction: Powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Size (Electronic Enclosure Only): 152 W x 112 H x 56 mm D (6.0 x 4.4 x 2.2")
Conduit Holes: (2) ½ NPT female (1) ¾ NPT female
Temperature: -40 to 85°C (-40 to 185°F)
RTD: Platinum 385, 1000O, 3-wire
Configuration: Via optional keypad or PC running software (Note: not all configuration parameters are available from the keypad – i.e. flow and temperature calibration and advanced filter settings)
Engineering Units Flow Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs, meters, cubic meters, liters, million liters, kg
Engineering Units Energy Meter: BTU, MBTU, MMBTU, Tons
Inputs/Outputs USB 2.0: For connection of a PC running configuration utility
    RS485: MODBUS RTU command set
    4 to 20 mA: 12-bit, internal power, can span negative to positive flow/energy rates
Transducers
Construction
    Standard (FDT-41 thru 46): NEMA 6 (IP67), PVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 60°C (-40 to 140°F)
    FDT-41 thru 46 with “-HT” option, FDT-47 and FDT-48: NEMA 6 (IP67), CPVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 90°C (-40 to 194°F)
    FDT-47 “-HT”: NEMA 6 (IP67), PTFE, polyimide, Nickel-plated brass cord grip, PFA cable jacket
    Temperature: -40 to 176°C (-40 to 350°F)
Frequency:
    FDT-41 thru 46: 2 MHz
    FDT-47: 1 MHz
    FDT-48: 500 KHz
Cables: RG59 coaxial, 75 Ω or twin axial, 78 Ω (optional armored conduit)
Cable Length: Standard 6 m (20') [300 m (990') maximum in 3 m (10') increments; submersible conduit limited to 30 m (100') for transducers]
Software Utilities Utilized to configure, calibrate and troubleshoot flowmeters. Connection via USB A/B cable; software is compatible with Windows 2000, Windows XP, Windows Vista® and Windows® 7
RS485 Network All FDT-40 meters come equipped with RS485 drivers and utilize a MODBUS RTU command set (data can be returned in single-precision, doubleprecision, integer or floating point values). Up to 126 units products can be run on a single daisy-chain network and be individually queried for flow rate, positive flow accumulator, negative flow accumulator and signal strength. Flow accumulators can be cleared at discrete addresses or globally. The RS485 network is also compatible with direct to Excel, application.
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
  
FDT-40E
판매 상담  
배송: 
 
 
Energy flowmeter display 95 to 264 Vac, temperature range 0 to 100°C (32 to 212°F)
  
FDT-40E-VDC
판매 상담  
배송: 
 
 
Energy flowmeter display 10 to 28 Vdc, temperature range 0 to 100°C (32 to 212°F)
  
FDT-40E-24VAC
6,618,290원
배송: 5 주
 
Energy flowmeter display 24 Vac, temperature range 0 to 100°C (32 to 212°F)
  
FDT-40E-HT
판매 상담  
배송: 
 
 
Energy flowmeter display 95 to 264 Vac, temperature range -40 to 177°C (-40 to 350°F)
  
FDT-40E-VDC-HT
6,367,620원
배송: 5 주
 
Energy flowmeter display 10 to 28 Vdc, temperature range -40 to 177°C (-40 to 350°F)
  
FDT-40E-24VAC-HT
6,618,290원
배송: 5 주
 
Energy flowmeter display 24 Vac, temperature range -40 to 177°C (-40 to 350°F)
Accessory Remote Transducers (Display Sold Separately)
Remote Transducers for ANSI Pipe (Display Sold Separately)
  
FDT-41-ANSI
판매 상담  
배송: 
 
 
Transducer for 1/2" ANSI pipe
  
FDT-42-ANSI
1,074,820원
배송: 2 주
 
Transducer for 3/4" ANSI pipe
  
FDT-43-ANSI
판매 상담  
배송: 
 
 
Transducer for 1" ANSI pipe
  
FDT-44-ANSI
판매 상담  
배송: 
 
 
Transducer for 1 1/4" ANSI pipe
  
FDT-45-ANSI
판매 상담  
배송: 
 
 
Transducer for 1 1/2" ANSI pipe
  
FDT-46-ANSI
판매 상담  
배송: 
 
 
Transducer for 2" ANSI pipe
Remote Transducers for Copper Pipe (Display Sold Separately)
  
FDT-41-CP
판매 상담  
배송: 
 
 
Transducer for 1/2" Copper pipe
  
FDT-42-CP
1,074,820원
배송: 2 주
 
Transducer for 3/4" Copper pipe
  
FDT-43-CP
판매 상담  
배송: 
 
 
Transducer for 1" Copper pipe
  
FDT-44-CP
판매 상담  
배송: 
 
 
Transducer for 1 1/4" Copper pipe
  
FDT-45-CP
판매 상담  
배송: 
 
 
Transducer for 1 1/2" Copper pipe
  
FDT-46-CP
판매 상담  
배송: 
 
 
Transducer for 2" Copper pipe
Remote Transducers for Tubing (Display Sold Separately)
  
FDT-41-TUBE
판매 상담  
배송: 
 
 
Transducer for 1/2" tubing
  
FDT-42-TUBE
판매 상담  
배송: 
 
 
Transducer for 3/4" tubing
  
FDT-43-TUBE
판매 상담  
배송: 
 
 
Transducer for 1" tubing
  
FDT-44-TUBE
판매 상담  
배송: 
 
 
Transducer for 1 1/4" tubing
  
FDT-45-TUBE
판매 상담  
배송: 
 
 
Transducer for 1 1/2" tubing
  
FDT-46-TUBE
판매 상담  
배송: 
 
 
Transducer for 2" tubing
Remote Transducers (Display Sold Separately)
Click to expand/minimize a list of what others bought with theFDT-47
FDT-47
1,609,650원
배송: 2 주
 
Transducer for 2 to 24" pipe
  
FDT-47-100FT
2,058,950원
배송: 6 주
 
Transducer for 2 to 24" pipe with 100 ft of cable
  
FDT-47-HT
6,306,130원
배송: 8 주
 
High temperature transducer for 2 to 24" pipe
  
FDT-47-HT-100FT
6,753,870원
배송: 8 주
 
High temperature transducer for 2 to 24" pipe with 100 ft of cable
  
FDT-48
2,583,940원
배송: 8 주
 
Transducer for pipes over 24"
  
FDT-48-100FT
3,037,980원
배송: 8 주
 
Transducer for pipe over 24" with 100 ft of cable
Accessories
  
FDT-40-PC-CABLE
117,370원
배송: 6 주
 
Optional USB PC programming cable
  
FDT-40-CABLE GLAND
61,530원
배송: 2 주
 
Optional cable gland
  
FDT-40-BHC
162,850원
배송: 5 주
 
Brad Harrison connector for the FDT-40 Series
  
FDT-40-RTDCONN
170,700원
배송: 6 주
 
RTD Pig Tail (connection adapter)
  
FDT-40-RTD1
1,066,720원
배송: 6 주
 
RTD kit, clamp-on, 130C, 1000Ω 6.1 m (20')
  
FDT-40-RTD2
1,338,210원
배송: 2 주
 
RTD kit, clamp-on, 200C, 1000Ω 6.1 m (20')
  
FDT-40-RTD3
1,962,780원
배송: 6 주
 
RTD kit, insertion, 3 x 1/4", 126C, 1000Ω Platinum RTD
Click to expand/minimize a list of what others bought with theFDT-GREASE
FDT-GREASE
120,020원
배송: 2 주
 
Replacement acoustic couplant 150 g (5.3 oz)
  
FDT-HT-GREASE
269,720원
배송: 2 주
 
High temperature acoustic couplant 56 g (2 oz)
Click to expand/minimize a list of what others bought with theFDT-NS-GREASE
FDT-NS-GREASE
120,020원
배송: 6 주
 
Non-silicone acoustic couplant 79 g (2.8 oz)
모든 가격은 원화로 표시되어 있습니다.
참고: Comes complete with operator’s manual. Transducers come with mounting gel.

Transducers sold separately.


제품 번호 생성기

제품 옵션을 선택하세요
옵션 선택:


(1) Pipe and Tubing Sizes 선택하기:
41 : 1/2 Inch
42 : 3/4 Inch
43 : 1 Inch
44 : 1 1/4 Inch
45 : 1 1/2 Inch
46 : 2 Inch
47 : 2 to 24 Inch
48 : Pipes over 24 inch

(2) Pipe and Tubing Material 선택하기:
ANSI : ANSI pipe
CP : Copper pipe
TUBE : Plastic tubing

(3) High Temperature 선택하기:
없음(공란으로 비워두기) : None
-HT : High temp transducers

(4) Cable Length 선택하기:
없음(공란으로 비워두기) : Standard 6 m (20 feet)
-100FT : 30 m (100 feet)
참고: 제품 구성 시 ‘판매 상담’으로 표시되어있는 제품은 영업부와 상담하십시오.
We noticed you are from the US. Visit your local site for regional offers and live support.