Strain/Microvoltmeter Indicator Controller
1/8 Din - Discontinued

DP2000-S Series

Strain/Microvoltmeter Indicator Controller, 1/8 Din | DP2000-S Series

Strain/Microvoltmeter Indicator Controller, 1/8 Din

페이지 하단에서 가격을 확인하세요.

1 year warranty
  • Adjustable 1 to 10 Vdc Bridge Excitation Supply
  • ±1999 or ±9999 Count Display Span
  • Seven Overlapping Gain Ranges
  • Front-Panel Accessible Zero and Span Adjustments
  • Resolution Down to 1 or 2 µV/Count
  • Strain-Gauge Sensitivity Down to 0.20 mV/V
  • Ratiometric Measurement
  • 1 or 0.2 mV/Count Analog Output
  • LED or LCD Display
  • Automatic Polarity
  • Display Hold and Test
  • Screw-Terminal Barrier Strip

설명

Starting from Apr 1st 2018, DP2000/9000 Series have been discontinued. As a possible substitute, please check out the DPPT Panel Meter or CNPT Controller for details.

The DP2000/9000-S is a meter/controller for use with pressure transducers and load cells which require bridge excitation and preamplification of microvolt signals. Deadload and tare adjustments make it suitable for weighing applications. Like process meters, it provides zero and span adjustments for direct readout in engineering units. It can also be used as a microvoltmeter with differential input. A universal 1/8 DIN case houses each meter. Choose any combination of display type (LED or LCD), operating power, input type and range, analog output, and digital or control outputs.

Excitation Supply and Preamplifier
The DP2000/9000-S provides a constant-voltage excitation supply, which is adjustable from 1 to 10V and can drive up to 30 mA. It also provides a high-impedance preamplifier, which is continuously adjustable so that signal levels from ±2.0 to ±500 mV can produce the fullscale display of ±1999 or ±9999 counts. At 10V excitation and maximum gain, full-scale readout can be obtained with strain-gauge sensitivity as low as 0.20 mV/V. An active filter is provided for noise reduction.

Bridge Connection
Bridges can be connected by 4 or 6 wires. In 6-wire connection, two lines sense the voltage applied to the bridge and compensate for lead resistance.

Resolution and Accuracy
Resolution for DP2000-S is one part in ±1999 counts, or 0.05% of full scale. Resolution for DP9000-S is one part in ±9999 counts, or 0.01% of full scale. Accuracy is 99.9% of reading. The measurement is ratiometric to reduce errors due to temperature and power-line variations. The same internal reference controls the meter gain and the excitation level.

SPECIFICATIONS
Gain Adjustment: Seven overlapping ranges with fine adjustment
Input Configuration: Differential, ratiometric
Zero Adjustment: ±225 µV/volt of excitation
Span Adjustment: 1 to 2.47 of preamp gain
Bias Current: 11 nA typ, 22 nA max
Noise Rejection
CMR, SIG GND to SIG LO: 80 dB, DC to 60 Hz
CMV, SIG GND to SIG LO: ±1 V, DC to 60 Hz
CMR, SIG GND to PWR GND: 120 dB
CMV, SIG GND to PWR GND: 1500 Vp per HV test, 354 Vp per IEC spacing
Accuracy at 25 °C
Error, Maximum ±0.05% of reading ±1 count (DP2); ±0.05% of reading ±2 counts (DP9)
Span Tempco: ±0.01% of reading/ °C
Zero Drift, Maximum: ±0.3 µV/ °C
Offset Drift, Maximum: ±(0.01% offset V ±0.01% FS V)/ °C
Step Response: 1 s to 99.9% of span
Warmup to Rated Accuracy: 30 min (DP2); 60 min (DP9)
Excitation
Configuration: Constant-voltage
Voltage Sense: Internal or remote
Voltage Range: Adjustable from 1 to 10V
Load Current, Maximum: 30 mA Conversion
Technique: Auto-zero, dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Models: 120, 240 or 24 Vac +10%/-15%, 49 to 440 Hz
DC Models: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp; 5 Vdc ±5%, non-isolated
Common Mode
Rejection: 120 dB
Environmental
Operating Temperature: 0 to 60 °C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 95% RH, non-condensing @ 40°C (104°F)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94V-0 UL-rated polycarbonate
가격 확인(원하는 수량을 기입하십시오.)
제품 번호/Desc.
수량
설명
DP2000-S1
판매 상담  
배송: 
 
 
Strain / Microvoltmeter Indicator/ Controller, 3-1/2 digit display, red LED display, 120 Vac power, 1 mV per count analog output, scalable strain/microvolt signal input, 499 mV max input span, 4 to 10 mV gain (no control output)
DP2000-S2
판매 상담  
배송: 
 
 
Strain / Microvoltmeter Indicator/ Controller, 3-1/2 digit display, red LED display, 120 Vac power, 1 mV per count analog output, scalable strain/microvolt signal input, 249 mV max input span, 8 to 20 mV gain (no control output)
DP2020-S2
판매 상담  
배송: 
 
 
Strain / Microvoltmeter Indicator/ Controller, 3-1/2 digit display, red LED display, 120 Vac power, 0 to 10 Vdc analog output, scalable strain/microvolt signal input, 249 mV max input span,8 to 20 mV gain (no control output)
DP9000-S2
판매 상담  
배송: 
 
 
Strain / Microvoltmeter Indicator/ Controller, 4 digit display, red LED display, 120 Vac power, 0.2 mV per count analog output, scalable strain/microvolt signal input, 249 mV max input span, 8 to 20 mV gain (no control output)
모든 가격은 원화로 표시되어 있습니다.
참고: Comes complete with operator’s manual.

제품 번호 생성기

제품 옵션을 선택하세요
옵션 선택:


(1) Display Resolution and Case Style 선택하기:
2 : ±1999 counts (3 1/2 digits)
9 : ±9999 counts (4 digits)

(2) Display & Power Options 선택하기:
0 : LED 120 Vac (49/440 Hz) (BQ20 or BQ90)
1 : LCD 120 Vac (49/440 Hz) (BQ21)
2 : LED 240 Vac (49/440 Hz) (BQ22 or BQ92)
3 : LCD 240 Vac (49/440 Hz) (BQ23)
4 : LED 9-32 Vdc (isolated) (BQ24 or BQ94)
5 : LCD 9-32 Vdc (isolated) (BQ25)
6 : LED 5 Vdc** (BQ26 or BQ96)
7 : LCD 5 Vdc** (BQ27)
8 : LED 24 Vac (BQ28 or BQ98)
9 : LCD 24 Vac (BQ29)
A : LED 26-56 Vdc (isolated) (BQ2A or BQ9A)
B : LCD 26-56 Vdc (isolated) (BQ2B)

(3) Analog Outputs 선택하기:
0 : 1mV/count (DP2) or 0.2mV/count (DP9) analog output non-isolated. (standard)
1 : 0-5 Vdc non-isolated (BA01)
2 : 0-10 Vdc non-isolated (BA01)
3 : 0-1 mA source or sink non-isolated (BA01)
4 : 4-20 mA source or sink non-isolated (BA01)
5 : 4-20 mA sink (high-compliance) non-isolated. (BA02)
6 : 4-20 mA ISOLATED (BA03)

(4) Control Outputs 선택하기:
0 : None
1 : Dual-setpoint 10 A relay. (BDT1)
2 : Proportional 4-20 mA control source or sink (BDP1)
3 : Time-proportional solid-state 2 A relay plus proportional 4-20 mA control source or sink. (BDP2)
4 : BCD (isolated latched buffered byte addressable). Includes 50-pin mass-termination connector. (BDD2)
5 : Single-setpoint 10 A relay (BDS1)

(5) Input Type and Range 선택하기:
S1 : Strain-gage/microvolt input plus excitation 499 mV
S2 : Strain-gage/microvolt input plus excitation 249 mV
S3 : Strain-gage/microvolt input plus excitation 124 mV
S4 : Strain-gage/microvolt input plus excitation 62.5 mV
S5 : Strain-gage/microvolt input plus excitation 31.2 mV
S6 : Strain-gage/microvolt input plus excitation 15.6 mV
S7 : Strain-gage/microvolt input plus excitation 7.8 mV

(6) Display Color 선택하기:
없음(공란으로 비워두기) : for Red Display (standard)
-G : Green Display
참고: 제품 구성 시 ‘판매 상담’으로 표시되어있는 제품은 영업부와 상담하십시오.