장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나은행 201-910031-70804

Process Receiver Indicator/Controller
1/8 DIN - Discontinued

DP2000-P, DP2000-E Series

Process Receiver Indicator/Controller, 1/8 DIN | DP2000-P, DP2000-E Series

Process Receiver Indicator/Controller, 1/8 DIN

페이지 하단에서 가격을 확인하세요.

1 year warranty
  • 10 or 15 Vdc Excitation Output (DP2000-E, DP9000-E)
  • ±1999 or ±9999 Count Display Span
  • Selectable Current Ranges From ±1 to ±50 mA
  • Selectable Voltage Ranges From ±0.5 to ±20 V
  • Built-In Shunts and Attenuators
  • Zero Adjustment to ±100% of Readout
  • Standard Signal Ranges of 4 to 20 mA, 10 to 50 mA, 1 to 5V or 0 to 10V
  • Front-Panel Accessible Zero and Span Adjust
  • 1 or 0.2mV/Count Analog Output
  • LED or LCD Display
  • Automatic Polarity
  • Display Hold and Test
  • Screw-Terminal Barrier Strip

설명

Starting from Apr 1st 2018, DP2000/9000 Series have been discontinued. As a possible substitute, please check out the DPPT Panel Meter or CNPT Controller for details.

The DP2000-P, DP9000-P is a process receiver with extensive zero and span adjustment capability for readout in engineering units. The more popular process signals are 4 to 20 mA, 10 to 50 mA, 1 to 5V and 0 to 10V. The DP2000-P, DP9000-P can also be scaled for other signal levels. Full-scale input ranges are selectable from ±1 to ±50 mA (current signal) or ±0.5 to ±20 V (voltage signal). Zero is adjustable up to ±100% of full-scale readout for every input range. A universal 1/8 DIN case houses each meter. Choose any combination of display type (LED or LCD), operating power, input type and range, analog output, and digital or control outputs.

The DP2000-E, DP9000-E is an enhanced version of the DP2000/DP9000-P with an excitation output for powering transmitters and active transducers. In many cases, this output can eliminate the need for a more expensive external supply. The output shares the ground of the signal input. Two output levels are jumper-selectable: 10 Vdc at up to 50 mA and 15 Vdc at up to 25mA.

Configuration and Calibration
The DP2000/DP9000-P and DP2000/DP9000-E includes configuration and calibration. Models can also be configured and scaled in the field. Full-scale signal, coarse-span and coarse-zero ranges are selected by plug-in jumpers. A complete set of internal shunts and attenuators are already on board. Fine-zero and fine-span potentiometers are accessible behind the lens to allow final calibration or field recalibration without removal of the panel meter.

SPECIFICATIONS
Conversion
Technique: Dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Models: 120, 240 or 24 Vac 10%/ -15%, 49 to 440 Hz
DC Models: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp; 5 Vdc ±5%, non-isolated
Common Mode
Voltage: 1500 Vp test (354 Vp per IEC spacing)
Rejection: 120 dB
Accuracy at 25°C
Error, Maximum: ±0.05% of reading ±1 count (DP2000); ±2 counts (DP9000)
Span Tempco: ±0.01% of reading/°C
Zero Drift, Maximum: ±0.01% of reading/°C
Offset Drift, Maximum: ±(0.01% offset V ±0.01% full scale V)/°C
Step Response: 1 s to 99.9% of span
Warmup to Rated Accuracy: 10 minutes (DP2000); 30 minutes (DP9000)
Environmental
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: To 95% RH, non-condensing @ 40°C (104°F)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94V-0 UL-rated polycarbonate
가격 확인(원하는 수량을 기입하십시오.)
제품 번호/Desc.
수량
설명
DP2000-P4
판매 상담  
배송: 
 
 
Process Receiver Indicator/ Controller, 3-1/2 digit display, red LED display, 120 Vac power, 1 mV per count analog output, scalable process signal input (from 1 to 5 Vdc and 8 to 230 counts/V) (no control output)
DP2000-P8
판매 상담  
배송: 
 
 
Process Receiver Indicator/ Controller, 3-1/2 digit display, red LED display, 120 Vac power, 1 mV per count analog output, scalable process signal input (from 4 to 20 mA and 2.5 to 70 counts/mA) (no control output)
DP2100-P8
판매 상담  
배송: 
 
 
Process Receiver Indicator/ Controller, 3-1/2 digit display, LCD display, 120 Vac power, 1 mV per count analog output, scalable process signal input (from 4 to 20 mA and 2.5 to 70 counts/mA) dual setpoint 10 A relay
DP2000-E4
판매 상담  
배송: 
 
 
Process Receiver with Excitation Indicator/ Controller, 3-1/2 digit display, red LED display, 120 Vac power, 1 mV per count analog output, scalable process signal input (from 1 to 5 Vdc and 8 to 230 counts/V) (no control output)
모든 가격은 원화로 표시되어 있습니다.
참고: Comes complete with operator’s manual.
 

제품 번호 생성기

제품 옵션을 선택하세요
옵션 선택:


(1) Display Resolution and Case Style 선택하기:
2 : ±1999 counts (3 1/2 digits)
9 : ±9999 counts (4 digits)

(2) Display & Power Options 선택하기:
0 : LED 120 Vac (49/440 Hz) (BQ20 or BQ90)
1 : LCD 120 Vac (49/440 Hz) (BQ21)
2 : LED 240 Vac (49/440 Hz) (BQ22 or BQ92)
3 : LCD 240 Vac (49/440 Hz) (BQ23)
4 : LED 9-32 Vdc (isolated) (BQ24 or BQ94)
5 : LCD 9-32 Vdc (isolated) (BQ25)
6 : LED 5 Vdc** (BQ26 or BQ96)
7 : LCD 5 Vdc** (BQ27)
8 : LED 24 Vac (BQ28 or BQ98)
9 : LCD 24 Vac (BQ29)
A : LED 26-56 Vdc (isolated) (BQ2A or BQ9A)
B : LCD 26-56 Vdc (isolated) (BQ2B)

(3) Analog Outputs 선택하기:
0 : 1 mV (DP2) or 0.2mV (DP9) analog output non-isolated. (standard)
1 : 0-5 Vdc non-isolated (BA01)
2 : 0-10 Vdc non-isolated (BA01)
3 : 0-1 mA source or sink non-isolated (BA01)
4 : 4-20 mA source or sink non-isolated (BA01)
5 : 4-20 mA sink (high-compliance) non-isolated. (BA02)
6 : 4-20 mA ISOLATED (BA03)

(4) Control Outputs 선택하기:
0 : None
1 : Dual-setpoint 10 A relay. (BDT1)
2 : Proportional 4-20 mA control source or sink (BDP1)
3 : Time-proportional solid-state 2 A relay plus proportional 4-20 mA control source or sink. (BDP2)
4 : BCD (isolated latched buffered byte addressable). Includes 50-pin mass-termination connector. (BDD2)
5 : Single-setpoint 10 A relay (BDS1)

(5) Input Type and Range 선택하기:
E1 : Process Signal Input plus Excitation Output 0.5 V
E2 : Process Signal Input plus Excitation Output 0.5 V
E3 : Process Signal Input plus Excitation Output 0.5 V
E4 : Process Signal Input plus Excitation Output 0.5 V
E5 : Process Signal Input plus Excitation Output 0.5 V
E6 : Process Signal Input plus Excitation Output 10.0 V
E7 : Process Signal Input plus Excitation Output 10.0 V
E8 : Process Signal Input plus Excitation Output 4 to 20 mA
E9 : Process Signal Input plus Excitation Output 4 to 20 mA
E10 : Process Signal Input plus Excitation Output 10 to 50 mA
E11 : Process Signal Input plus Excitation Output 10 to 50 mA
P1 : Process Signal Input 0.5 V
P2 : Process Signal Input 0.5 V
P3 : Process Signal Input 0.5 V
P4 : Process Signal Input 5.0 V
P5 : Process Signal Input 5.0 V
P6 : Process Signal Input 10.0 V
P7 : Process Signal Input 10.0 V
P8 : Process Signal Input 40 to 20 mA
P9 : Process Signal Input 40 to 20 mA
P10 : Process Signal Input 10 to 50 mA
P11 : Process Signal Input 10 to 50 mA

(6) Display Color 선택하기:
없음(공란으로 비워두기) : for Red Display (standard)
-G : Green Display
참고: 제품 구성 시 ‘판매 상담’으로 표시되어있는 제품은 영업부와 상담하십시오.