장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나은행 201-910031-70804

1/8 DIN Economical Digital Meters for Temperature, Process or Electrical Measurement - Discontinued

DP18 Series

Economical Meters  for Temperature, Process or Electrical Measurement | DP18 Series

페이지 하단에서 가격을 확인하세요.

1 year warranty CE
  • Modular Design
  • Options for Alarms, Analog Output of Communications
  • 3 1/2-Digit LED Available in Red or Green Displays
  • Removable Screw-Clamp Cable Connector
압력 & 스트레인 측정 장비 - 관련 제품 보기

설명

Starting from Sept 30th 2017, DP18 Series will be discontinued. As an upgrade substitute, please check out the DP20 Series for details.

The DP18 series offers a modular design for easy selection and installation of options and inputs. Field installable signal conditioner cards provide the large user or OEM the ability to stock options and spare signal conditioner cards for conversion of input type, meter function or repair. For customers who require the flexibility to add options to the meter as requirements become more demanding, the DP18’s field-installable analog outputs, relays and communications offer an economical solution.

The DP18 series is a complete family of panel meters with input cards for voltage, process and temperature measurement and control. The signal conditioners for voltage will measure ac or dc voltages or true RMS. Signal conditioners for process inputs accept low level voltage or current which can be scaled for engineering units. Temperature meters will provide accurate measurement of thermocouples or RTD’s. Other inputs include differential process, load cells or potentiometers. Combined with OMEGA’s wide selection of transducers, the DP18 series is the single solution for process measurement.

Base Model Input Base Model Input
DP18-PProcess signalDP18-RVac RMS current
DP18-DVdc voltageDP18-RTac RMS current (external CT)
DP18-DCdc currentDP18-JType J thermocouple
DP18-DSdc current (external shunt)DP18-KType K thermocouple
DP18-AVac voltageDP18-TType T thermocouple
DP18-ACac currentDP18-EType E thermocouple
DP18-ATac current (external CT)DP18-RType R thermocouple
DP18-RVac RMS voltageDP18-SType S thermocouple
DP18-LLoad cell (strain gage)DP18-MRTD
DP18-QOhmmeter  


Thermocouple Inputs
Model No. Range Resolution Accuracy Signal
Cond.
DP18-JC-50 to 600°C1°C±0.5% rdg ±1 countBD18-22
DP18-KC0 to 1250°C1°CBD18-23
DP18-TC-50 to 400°C1°CBD18-24
DP18-EC0 to 650°C1°C±0.2% rdg ±1 countBD18-25
DP18-SC0 to 1750°C1°C±1.5% rdg ±1 count (0 to 260°C)
±0.5% rdg ±1 count (260 to 970°C)
±0.1% rdg ±1 count (970 to 1750°C)
BD18-26
DP18-RC250 to 1750 °C1°C±2% rdg ±1 count (250 to 500°C)
±0.5% rdg ±1 count (500 to 1000°C)
±0.2% rdg ±1 count (1000 to 1750°C)
BD18-27


RTD (Pt100; Alpha = 0.00385; 2- or 3-wire) Inputs
Model No. Range Resolution Accuracy Signal
Cond.
DP18-M1C-200 to 650°C1°C1°C ±1 countBD18-20C
DP18-M1F-200 to 400°F1°F1°F ±1 countBD18-20F
DP18-M2-150.0 to 199.9°C0.1°C0.4°C ±1 countBD18-21


Process Signal Inputs
Model No. Range Input
Impedance
Excitation Accuracy Signal
Cond.
DP18-P10 to 1 V1.1 MΩ10 to 24 Vdc,
50 mA max
±0.15% rdg
±1 count
BD18-32
DP18-P20 to 5 V/1 to 5 V1.1 MΩ
DP18-P30 to 1 mA100 Ω
DP18-P40 to 5 mA/1 to 5 mA100 Ω
DP18-P50 to 20 mA/4 to 20 mA24.9 Ω
DP18-P60 to 50 mA/10 to 50 mA10 Ω
DP18-P70 to 20/0 to 200 Vdc1 MΩBD18-36/A


Potentiometer (Potentiometric Transducers)*
Model No. Input Excitation Accuracy Signal
Cond.
DP18-P83-Wire Pot.5 Vdc @50 mA max.±0.15% rdg
±1 count
BD18-90


Differential Process*
Model No. Range Accuracy Signal
Cond.
DP18-P90 to 20 mA±0.15% rdg
±1 count
BD18-35
*All process input meters are fully scalable from –1999 to +1999 with selectable decimal point and zero and span adjustments

Strain Gage/Load Cell
Model No. Load Cell
Impedance
Input
Impedance
Resolution Sensitivity Accuracy Excitation Signal
Cond.
DP18-L1350 Ω20 MΩ5 µV/ct10 mV0.15% rdg
±1 count
10 to 24 Vdc @
50 mA max.
BD18-80


DC Voltage Inputs
Model No. Range Input
Impedance
Resolution Accuracy Signal Cond.
DP18-DV1199.9 mV dc100 MΩ0.1 mV0.05%
of reading
±1 count
BD18-02
DP18-DV21.999 Vdc1000 MΩ1.0 mVBD18-01
DP18-DV319.99 Vdc1 MΩ10 mV
DP18-DV4199.9 V1 MΩ100 mV
DP18-DV5600 Vdc1 MΩ1 V
DP18-DV6to 2/0 to 10/0 to 100
/0 to 600 Vdc*
1 MΩ±1 countsBD18-11
DP18-DV7<2 Vdc*10 MΩ±2 counts0.15% ±1 countBD18-12
*Fully scalable from –1999 to +1999, selectable decimal point, zero and span adjustments

DC Current Inputs
Model No. Range Input
Impedance
Resolution Accuracy Signal Cond.
DP18-DC11.999 mA150 Ω1 µA0.05% rdg
±1 count
BD18-10
DP18-DC219.99 mA15 Ω10 µA
DP18-DC3199.9 mA1.5 Ω100 µA
DP18-DC41999 mA0.15 Ω1 mA


DC Current Inputs for Use with External Shunt
Model No. Range (Amps dc) Input
Impedance
Resolution Accuracy Signal Cond.
DP18-DS10/20/40/60/80
100/150/200
250/400/600/ 800
1000/1500/2000
20 MΩ1 count0.2% rdg
±1 count
BD18-03
Note: Requires external shunt of 60, 100 or 150 mV; range is jumper selected. To order dc shunts, see Accessories Table

MOST POPULAR MODELS
Model No. Description
THERMOCOUPLE INPUT
DP18-KC-AO1Type K thermocouple with 4 to 20 analog output
DP18-JC-R2Type J thermocouple with dual setpoints
RTD INPUT
DP18-M1C-AO1RTD input, 1° resolution with 4 to 20 mA analog output, °C
DP18-M1F-R2RTD input, 1° resolution with dual setpoint, °F
PROCESS INPUT
DP18-P5-AO1Process input range 4 to 20 mA with 4 to 20 mA analog output
DP18-P5-R2Process input range 4 to 20 mA with dual setpoints
DC VOLTAGE INPUT
DP18-DV1-AO1dc voltage range 199.9 mV with 4 to 20 analog output
DP18-DV4-R2dc voltage range 199.9 Vdc with dual setpoints
DC CURRENT INPUT
DP18-DC1-AO1dc current range 1.999 mA with 4 to 20 analog output
DP18-DC1-R2dc current range 1.999 mA with dual setpoints


Options for All Models

Power Options
Order Suffix Description
-220220 Vac
-2424 Vac
-4848 Vac
-12VDC12 Vdc isolated
-15/30VDC15-30 Vdc isolated
-24/65VDC24-65 Vdc isolated
Note: Standard power is 110 Vac

Analog Output Options*
Order Suffix Description
-AO1Milliamp sink 0 to 20 mA max.
-AO2Milliamp source 0 to 20 mA max.
-AO3Voltage 0 to 10 Vdc max.
-APH2Analog peak hold


Control Output/Communications Options*
Order Suffix Description
-R1Single setpoint
-R2Dual setpoint
-APH1Analog peak hold
*A maximum of one analog output option and one control output/communications option can be specified per meter

Display Options
Order Suffix Description
-GRGreen display
-DNDisplay hold
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
Thermocouple Inputs
  
DP18-JC
판매 상담  
배송: 
 
 
J T/C meter
  
DP18-JC-AO1
판매 상담  
배송: 
 
 
J T/C meter with analog output option:Milliamp sink 0 to 20 mA max.
  
DP18-JC-AO1-R1
판매 상담  
배송: 
 
 
J T/C meter with analog output option:Milliamp sink 0 to 20 mA max. and relay output for Setpoint
  
DP18-JC-AO2
판매 상담  
배송: 
 
 
J T/C meter with analog output option:Milliamp source 0 to 20 mA max.
  
DP18-JC-R2
판매 상담  
배송: 
 
 
Type J thermocouple with dual setpoints
  
DP18-KC
판매 상담  
배송: 
 
 
K T/C meter
  
DP18-KC-220-R1
판매 상담  
배송: 
 
 
K T/C meter, 220Vac power, Relay output for Setpoint
  
DP18-KC-AO2
판매 상담  
배송: 
 
 
K T/C meter with analog output option:Milliamp source 0 to 20 mA max.
  
DP18-TC
판매 상담  
배송: 
 
 
T T/C meter
RTD Inputs
  
DP18-M1C-AO1
판매 상담  
배송: 
 
 
RTD input, 1° resolution with 4 to 20 mA analog output, °C
  
DP18-M1C-R1
판매 상담  
배송: 
 
 
RTD input, 1° resolution with Relay output for Setpoint
  
DP18-M1F
판매 상담  
배송: 
 
 
RTD, resolution 1°F
  
DP18-M1F-AO1
판매 상담  
배송: 
 
 
RTD, resolution 1°F meter with analog output option:Milliamp sink 0 to 20 mA max.
  
DP18-M1F-220
판매 상담  
배송: 
 
 
RTD, resolution 1°F for 220Vac Power
  
DP18-M2
판매 상담  
배송: 
 
 
RTD, resolution 0.1°C
  
DP18-M2-220
판매 상담  
배송: 
 
 
RTD, resolution 0.1°C for 220Vac Power
  
DP18-M2-AO1
판매 상담  
배송: 
 
 
RTD, resolution 0.1°C meter with analog output option:Milliamp sink 0 to 20 mA max.
  
DP18-M2-AO3
판매 상담  
배송: 
 
 
RTD, resolution 0.1°C meter with analog output option:Voltage 0 to 10 Vdc max.
Potentiometer (Potentiometric Transducers)
  
DP18-P8
판매 상담  
배송: 
 
 
Potentiometer
Process Signal Input
  
DP18-P5
판매 상담  
배송: 
 
 
0 to 20 mA/4 to 20 mA Range
  
DP18-P5-AO2
판매 상담  
배송: 
 
 
0 to 20 mA/4 to 20 mA Range with Analog output: Milliamp source 0 to 20 mA max.
  
DP18-P5-A03-R1
판매 상담  
배송: 
 
 
0 to 20 mA/4 to 20 mA Range with Analog output: Voltage 0 to 10 Vdc max. and single relay output setpoint
  
DP18-P5-R2
판매 상담  
배송: 
 
 
Process input range 4 to 20 mA with dual setpoints
Differential Process
  
DP18-P9-AO2
판매 상담  
배송: 
 
 
0 to 20 mA Range with Analog output: Milliamp source 0 to 20 mA max.
Strain Gage/Load Cell
  
DP18-L1-DN
판매 상담  
배송: 
 
 
Load cell meter with Display Hold
Ohmmeter
  
DP18-Q1
판매 상담  
배송: 
 
 
Ohmmeter, 0 to 199.9 ohms
  
DP18-Q1-GR
판매 상담  
배송: 
 
 
Ohmmeter, 0 to 199.9 ohms with Green Display
  
DP18-Q2
판매 상담  
배송: 
 
 
Ohmmeter, 0 to 1999 ohms
  
DP18-Q3
판매 상담  
배송: 
 
 
Ohmmeter, 0 to 19.99 kohms
  
DP18-Q4
판매 상담  
배송: 
 
 
Ohmmeter, 0 to 199.9 kohms
DC Voltage Inputs
  
DP18-DV1
판매 상담  
배송: 
 
 
DC voltmeter, 199.9 mV
  
DP18-DV1-R1
판매 상담  
배송: 
 
 
DC voltmeter, 199.9 mV with Relay Output for Setpoint
  
DP18-DV2
판매 상담  
배송: 
 
 
DC voltmeter, 1.999 V
  
DP18-DV3
판매 상담  
배송: 
 
 
DC voltmeter, 19.99 V
  
DP18-DV4
판매 상담  
배송: 
 
 
DC voltmeter, 199.9 V
  
DP18-DV5
판매 상담  
배송: 
 
 
DC voltmeter, 600 V
  
DP18-DV6
판매 상담  
배송: 
 
 
Fully Scalable DC voltmeter with jumper selectable ranges of 0 to 2/0 to 10/0 to 100/0 to 600
  
DP18-DV7
판매 상담  
배송: 
 
 
Fully Scalable DC voltmeter for inputs less than 2 Vdc.
DC Current Inputs
  
DP18-DC1
판매 상담  
배송: 
 
 
DC ammeter, 1.999 mA
  
DP18-DC2
판매 상담  
배송: 
 
 
DC ammeter, 19.99 mA
  
DP18-DC3
판매 상담  
배송: 
 
 
DC ammeter, 199.9 mA
  
DP18-DC4
판매 상담  
배송: 
 
 
DC ammeter, 1999 mA
DC Current Inputs for Use with External Shunt
  
DP18-DS
판매 상담  
배송: 
 
 
AMPS DC :10/20/40/60/80, 100/150/200, 250/400/600/ 800, 1000/1500/2000
  
DP18-DS-GR
판매 상담  
배송: 
 
 
Green Display, AMPS DC :10/20/40/60/80, 100/150/200, 250/400/600/ 800, 1000/1500/2000
Accessories - Current Shunts (100mV output)
Click to expand/minimize a list of what others bought with theDCS100-10
DCS100-10
판매 상담  
배송: 
 
 
Shunts, 10A
  
DCS100-20
108,690원
배송: 2 주
 
Shunts, 20A
  
DCS100-40
판매 상담  
배송: 
 
 
Shunts, 40A
  
DCS100-60
판매 상담  
배송: 
 
 
Shunts, 60A
  
DCS100-80
판매 상담  
배송: 
 
 
Shunts, 80A
  
DCS100-100
판매 상담  
배송: 
 
 
Shunts, 100A
  
DCS100-150
판매 상담  
배송: 
 
 
Shunts, 150A
  
DCS100-200
판매 상담  
배송: 
 
 
Shunts, 200A
  
DCS100-250
판매 상담  
배송: 
 
 
Shunts, 250A
  
DCS100-400
155,970원
배송: 2 주
 
Shunts, 400A
  
DCS100-600
판매 상담  
배송: 
 
 
Shunts, 600A
  
DCS100-800
판매 상담  
배송: 
 
 
Shunts, 800A
  
DCS100-1000
판매 상담  
배송: 
 
 
Shunts, 1000A
  
DCS100-1500
판매 상담  
배송: 
 
 
Shunts, 1500A
  
DCS100-2000
판매 상담  
배송: 
 
 
Shunts, 2000A

제품 번호로 주문하기

제품 번호
수량
제품 번호
수량


모든 가격은 원화로 표시되어 있습니다.

제품 번호 생성기

제품 옵션을 선택하세요
옵션 선택:


(1) Input Type 선택하기:
JC : J Thermocouple range -50 to 600°C
KC : K Thermocouple range 0 to 1250°C
TC : T Thermocouple range -50 to 400°C
EC : E Thermocouple range 0 to 650°C
SC : S Thermocouple range 0 to 1750°C
RC : R Thermocouple range 250 to 1750 °C
M1C : RTD range -200 to 650°C
M1F : RTD range -200 to 400°F
M2 : RTD range -150.0 to 199.9°C
P1 : Process signal input range 0 to 1V
P2 : Process signal input range 0 to 5 V/1 to 5V
P3 : Process signal input range 0 to 1 mA
P4 : Process signal input range 0 to 5 mA/1 to 5 mA
P5 : Process signal input range 0 to 20 mA/4 to 20 mA
P6 : Process signal input range 0 to 50 mA/10 to 50 mA
P7 : Process signal input range 0 to 20/0 to 200 Vdc
P8 : Potentiometer 3-wire
P9 : Differential process range 0 to 20 mA
Q1 : Ohm meter range 0 to 199.9
Q2 : Ohm meter range 0 to 1999
Q3 : Ohm meter range 0 to 19.99
Q4 : Ohm meter range 0 to 199.9
DV1 : DC Voltage input range 199.9 mVdc
DV2 : DC Voltage input range 1.999 Vdc
DV3 : DC Voltage input range 19.99 Vdc
DV4 : DC Voltage input range 199.9V
DV5 : DC Voltage input range 600 Vdc
DV6 : DC Voltage input range (0 to 2) (0 to 10) (0 to 100) (0 to 600) Vdc
DV7 : DC Voltage input range <2 Vdc
DC1 : DC Current input range 1.999 mA
DC2 : DC Current input range 19.99 mA
DC3 : DC Current input range 199.9 mA
DC4 : DC Current input range 1999 mA
DS : DC Current input range (Amps DC) 10/20/40/60/80 100/150/200 250/400/600/800 1000/1500/2000
AV1 : AC Voltage input range 1.999V
AV2 : AC Voltage input range 19.99V
AV3 : AC Voltage input range 199.9V
AV4 : AC Voltage input range 500V
AC1 : AC Current input range 1.999 mA
AC2 : AC Current input range 19.99 mA
AC3 : AC Current input range 199.9 mA
AC4 : AC Current input range 500 mA
AT1 : AC Current input (For use with external current transformer) range 5/10/15/25/40/50/60/100/150/250/400/500/600/1000/1500
AT2 : AC Current input (For use with external current transformer) range 5/10/15/25/40/50/60/100/150/250/400/500/600/1000/1500
RV1 : AC RMS Voltage input range 1.999 mA
RV2 : AC RMS Voltage input range 19.99 mA
RV3 : AC RMS Voltage input range 199.9 mA
RV4 : AC RMS Voltage input range 500 mA
RT1 : AC RMS current input (For use with external transformer) range 5/10/15/25/40/50/60/100/150/250/400/500/600/1000/1500

(2) Power Options 선택하기:
없음(공란으로 비워두기) : None
-220 : 220 Vac
-24 : 24 Vac
-48 : 48 Vac
-12VDC : 12 Vdc isolated
-15/30VDC : 15 to 30 Vdc isolated
-24/65VDC : 24 to 65 Vdc isolated

(3) Analog Output Option 선택하기:
없음(공란으로 비워두기) : None
-AO1 : Milliamp sink 0 to 20 mA max
-AO2 : Milliamp source 0 to 20 mA max
-AO3 : Voltage 0 to 10 Vdc max
-APH2 : Analog peak hold

(4) Control Output/Communications Options 선택하기:
없음(공란으로 비워두기) : None
-R1 : Single setpoint
-R2 : Dual setpoint
-APH1 : Analog peak hold

(5) Display Options 선택하기:
없음(공란으로 비워두기) : None
-GR : Green display
-DN : Display hold
참고: 제품 구성 시 ‘판매 상담’으로 표시되어있는 제품은 영업부와 상담하십시오.

제품 메뉴얼:

다운로드 DP18 SERIES - OPTIONS A01 / A02 / A03 ANALOG OUTPUT OPTIONS
다운로드 DP18 SERIES - MODEL DP18-AC1 / -AC2 / -AC3 / -AC4 AC MILLIAMMETER
다운로드 DP18 SERIES - OPTION APH1 ANALOG PEAK HOLD OPTION
다운로드 DP18 SERIES - OPTION APH2 ANALOG PEAK HOLD OPTION
다운로드 DP18 SERIES - MODEL DP18-AT2 AC AMMETER
다운로드 DP18 SERIES - MODEL DP18-AV1 / -AV2 / -AV3 / -AV4 AC VOLTMETER
다운로드 DP18 SERIES - MODEL DP18-DC1 / -DC2 / -DC3 / -DC4 DC MILLIAMMETER
다운로드 DP18 SERIES - MODEL DP18-DC DC AMMETER
다운로드 DP18 SERIES - MODEL DP18-DV1 DC MILLIVOLTMETER
다운로드 DP18 SERIES - MODEL DP18-DV2 / -DV3 / -DV4 / -DV5 DC VOLTMETERS
다운로드 DP18 SERIES - MODEL DP18-DV6 PROCESS INDICATOR
다운로드 DP18 SERIES - MODEL DP18-DV7 PROCESS INDICATOR
다운로드 DP18 SERIES - MODEL DP18-JC / -KC / -TC / -EC THERMOCOUPLE INPUT TEMPERATURE INDICATOR
다운로드 DP18 SERIES - MODEL DP18-L1 STRAIN GAUGE / LOAD CELL INDICATOR
다운로드 DP18 SERIES - MODEL DP18-M1 / M2 RTD INPUT TEMPERATURE INDICATOR
다운로드 DP18 SERIES - MODEL DP18-M1F RTD INPUT TEMPERATURE INDICATOR
다운로드 DP18 SERIES - MODEL DP18-P1 / -P2 / -P3 / -P4 / -P5 / -P6 PROCESS INDICATOR
다운로드 DP18 SERIES - MODEL DP18-P7 PROCESS INDICATOR
다운로드 DP18 SERIES - MODEL DP18-P8 PROCESS INDICATOR FOR POTENTIONMETRIC TRANSDUCERS
다운로드 DP18 SERIES - MODEL DP18-Q1 / -Q2 / -Q3 / -Q4 OHMETER
다운로드 DP18 SERIES - OPTIONS R1 / R2 SINGLE & DUAL SETPOINT OPTIONS
다운로드 DP18 SERIES - MODEL DP18-RC THERMOCOUPLE INPUT TEMPERATURE INDICATOR
다운로드 DP18 SERIES - MODEL DP18-RT1 TRUE RMS AMMETER
다운로드 DP18 SERIES - MODEL DP18-RV1 / -RV2 / -RV3 / -RV4 TRUE RMS VOLTMETER
다운로드 DP18 SERIES - MODEL DP18-SC THERMOCOUPLE INPUT TEMPERATURE INDICATOR
We noticed you are from the US. Visit your local site for regional offers and live support.