장바구니  |  연락하기  |  도움  | 
1588 8983  | 
전화번호: 1588 8983
계좌번호:하나은행 201-910031-70804

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners

DRLP Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners | DRLP Series

498,900원 DRLP-MV1

1 year warranty CE
  • ±0.03% Accuracy (Typical)
  • ±0.01% Linearity
  • 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection
  • ANSI/IEEE C37.90.1 Transient Protection
  • Wide Loop Supply Voltage, 10.8V to 60V
  • 5-Pole Low-Pass Filtering
  • Up to 160 dB CMR
  • 85dB NMR at 60Hz, 80dB at 50Hz
  • Protected Against Reverse Connection of Loop Voltage
  • -40 to 80°C (-40 to 176°F) Operating Temperature
  • Mounts on DIN Rail EN 50022, 35 x 7.5 or 35 x 15
  • CE Compliant
  • Manufactured per RoHS Directive 2002/95/EC
트렌스미터 - 관련 제품 보기

설명

The new DRLP Series of loop powered 2-wire transmitters consists of seven family groups with a total of 48 transmitter models that interface to a wide variety of voltage, current, temperature and position measuring devices. The DRLP Series provides superior specifications such as ±0.03% accuracy, five poles of filtering, 1500 Vrms continuous isolation, low output noise, and much more. The DRLP Series 2-wire transmitter conditions and sends analog signals from sensors located in the “field” to monitoring and control equipment, usually computers, located thousands of feet away in central control areas. The DRLP Series accepts a wide range of inputs, including millivolt, volt, milliamp, thermocouple, RTD, potentiometer, and slide wire. It operates on power from a 2-wire signal loop and modulates the supply current to represent the input signal within a 4 to 20-milliamp range. Two-wire transmission loops are very economical methods for connecting sensors to distant control rooms. Since the DRLP Series operates from the signal loop current, no additional, expensive power and wiring are required. Only low cost, twisted pair wiring is needed.

DRLP Loop Drive Capability
The DRLP Series transmitter’s wide range of loop supply voltage (10.8V to 60V) makes it a versatile device which can be used in most any current loop. The maximum loop resistance is determined by subtracting the transmitter’s minimum loop supply voltage from the total loop supply voltage and dividing the result by the maximum loop current (see graph). The low loop supply voltage of 10.8V allows the DRLP to be used in applications with low output power supplies and the high Loop Supply Voltage of 60V allows use in applications with long distance current loops.

COMMON SPECIFICATIONS
Input Protection
  Continuous: 240 Vrms maximum
  Transient: ANSI/IEEE C37.90.1
CMV, Input to Output
  Continuous: 1500 Vrms maximum
  Transient: ANSI/IEEE C37.90.1
Noise
  Output: 100 kHz:3µArms
Output Range: 4 to 20 mA
Output Protection
  Reverse Polarity: Continuous
  Over-Voltage: 240 Vrms continuous
  Transient: ANSI/IEEE C37.90.1
Loop Supply Voltage: 10.8V to 60V
Loop Supply Sensitivity: ±0.0005%/V
Turn-On Delay: 400 ms
Environmental
  Operating Temperature Range: -40 to 80°C (-40 to 176°F)
  Storage Temperature Range: -40 to 80°C (-40 to 176°F)
Relative Humidity: 0 to 95% non-condensing
Emissions EN61000-6-4: ISM, Group 1
  Radiated, Conducted: Class A
Immunity EN61000-6-2: ISM, Group 1
  RF: Performance A ±0.5% span error
  ESD, EFT: Performance B
Mechanical Dimensions: 75 H x 22.5 W x 105 mm D (2.95 x 0.89 x 4.13")
Mounting: DIN EN 50022 35 x 7.5 mm or 35 x 15 mm rail

See attached PDF for detailed Transmitter Specifications
가격 확인(원하는 수량을 기입하십시오.)

다른 고객님이 함께 구매하신 제품 : 이 아이콘을 클릭하시면 기존 고객들께서 이 제품을 주문할 때 함께 구매하신 제품리스트가 보입니다.

제품 번호/Desc.
수량
설명
DRLP-MV/DRLP-V (Voltage Input)
  
DRLP-MV1
498,900원
배송: 8 주
 
±10 mV Input Range
  
DRLP-MV2
498,900원
배송: 8 주
 
±50 mV Input Range
  
DRLP-MV3
498,900원
배송: 8 주
 
±100 mV Input Range
  
DRLP-MV4
498,900원
배송: 8 주
 
0 to 10 mV Input Range
  
DRLP-MV5
498,900원
배송: 8 주
 
0 to 50 mV Input Range
  
DRLP-MV6
498,900원
배송: 8 주
 
0 to 100 mV Input Range
  
DRLP-V1
498,900원
배송: 8 주
 
±1V Input Range
  
DRLP-V2
498,900원
배송: 8 주
 
±5V Input Range
  
DRLP-V3
498,900원
배송: 8 주
 
±10V Input Range
  
DRLP-V4
498,900원
배송: 8 주
 
0 to 1V Input Range
  
DRLP-V5
498,900원
배송: 8 주
 
0 to 5V Input Range
  
DRLP-V6
498,900원
배송: 8 주
 
0 to 10V Input Range
  
DRLP-V7
498,900원
배송: 8 주
 
±20V Input Range
  
DRLP-V8
498,900원
배송: 8 주
 
0 to 20V Input Range
DRLP-C (Current Input)
  
DRLP-C1
559,620원
배송: 8 주
 
4 to 20 mA Input Range
  
DRLP-C2
559,620원
배송: 8 주
 
0 to 20 mA Input Range
DRLP-RTD (Pt RTD Input)
  
DRLP-RTD1
564,790원
배송: 8 주
 
100 Ω Pt -100 to 100°C (-148 to 212°F) Input Range
  
DRLP-RTD2
564,790원
배송: 8 주
 
100 Ω Pt 0 to 100°C (32 to 212°F) Input Range
  
DRLP-RTD3
564,790원
배송: 8 주
 
100 Ω Pt 0 to 200°C (32 to 392°F) Input Range
  
DRLP-RTD4
564,790원
배송: 8 주
 
100 Ω Pt 0 to 600°C (32 to 1112°F) Input Range
  
DRLP-RTD5
564,790원
배송: 8 주
 
100 Ω Pt 0 to 400°C (32 to 752°F) Input Range
DRLP-RTD6 (Ni RTD Input)
  
DRLP-RTD6
564,790원
배송: 8 주
 
120 Ω Ni 0 to 300°C (32 to 572°F) Input Range
DRLP-P (Potentiometer Input)
  
DRLP-P1
527,130원
배송: 8 주
 
0 to 100Ω Input Range
  
DRLP-P2
527,130원
배송: 8 주
 
0 to 500Ω Input Range
  
DRLP-P3
527,130원
배송: 8 주
 
0 to 1 kΩ Input Range
  
DRLP-P4
527,130원
배송: 8 주
 
0 to 10 kΩ Input Range
DRLP-ITC (Non-Linearized Thermocouple Input)
  
DRLP-ITC-J
621,380원
배송: 8 주
 
J T/C, -100 to 760°C (-148 to 1400°F) Input Range
  
DRLP-ITC-K
621,380원
배송: 8 주
 
K T/C, -100 to 1350°C (-148 to 2462°F) Input Range
  
DRLP-ITC-T
621,380원
배송: 8 주
 
T T/C, -100 to 400°C (-148 to 752°F) Input Range
  
DRLP-ITC-E
621,380원
배송: 8 주
 
E T/C, 0 to 900°C (32 to 1652°F) Input Range
  
DRLP-ITC-R
621,380원
배송: 8 주
 
R T/C, 0 to 1750°C (32 to 3182°F) Input Range
  
DRLP-ITC-S
621,380원
배송: 8 주
 
S T/C, 0 to 1750°C (32 to 3182°F) Input Range
  
DRLP-ITC-B
621,380원
배송: 8 주
 
B T/C, 0 to 1800°C (32 to 3272°F) Input Range
  
DRLP-ITC-N
621,380원
배송: 8 주
 
N T/C, -100 to 1300°C (-148 to 2372°F) Input Range
DRLP-LTC (Linearized Thermocouple Input)
  
DRLP-LTC-J1
641,990원
배송: 8 주
 
J T/C, 0 to 760°C (32 to 1400°F) Input Range
  
DRLP-LTC-J2
641,990원
배송: 2 주
 
J T/C, -100 to 300°C (-148 to 572°F) Input Range
  
DRLP-LTC-J3
641,990원
배송: 8 주
 
J T/C, 0 to 500°C (32 to 932°F) Input Range
  
DRLP-LTC-K1
583,610원
배송: 8 주
 
K T/C, 0 to 1000°C (32 to 1832°F) Input Range
  
DRLP-LTC-K2
583,610원
배송: 8 주
 
K T/C, 0 to 500°C (32 to 932°F) Input Range
  
DRLP-LTC-K3
583,610원
배송: 8 주
 
K T/C, -100 to 1350°C (-148 to 2462°F) Input Range
  
DRLP-LTC-K4
583,610원
배송: 8 주
 
K T/C, 0 to 1200°C (32 to 2192°F) Input Range
  
DRLP-LTC-T1
583,610원
배송: 8 주
 
T T/C, -100 to 400°C (-148 to 752°F) Input Range
  
DRLP-LTC-T2
583,610원
배송: 8 주
 
T T/C, 0 to 200°C (32 to 392°F) Input Range
  
DRLP-LTC-E
641,990원
배송: 8 주
 
E T/C, 0 to 1000°C (32 to 1832°F) Input Range
  
DRLP-LTC-R
583,610원
배송: 8 주
 
R T/C, 500 to 1750°C (932 to 3182°F) Input Range
  
DRLP-LTC-S
583,610원
배송: 8 주
 
S T/C, 500 to 1750°C (932 to 3182°F) Input Range
  
DRLP-LTC-B
641,990원
배송: 8 주
 
B T/C, 500 to 1800°C (932 to 3272°F) Input Range
  
DRLP-LTC-N
583,610원
배송: 8 주
 
N T/C, -100 to 1300°C (-148 to 2372°F) Input Range
ACCESSORIES
  
RAIL-35-1
24,850원
배송: 2 주
 
35 mm DIN rail, 1 m (3.3') length
Click to expand/minimize a list of what others bought with theRAIL-35-2
RAIL-35-2
50,020원
배송: 2 주
 
35 mm DIN rail, 2 m (6.6') length
모든 가격은 원화로 표시되어 있습니다.
주문 예: (1) DRLP-MV1 ±10 mV Input Range, 498,900원  plus (1) RAIL-35-1 35 mm DIN rail, 1 m (3.3') length, 24,850원, 498,900 + 24,850 = 523,750원

제품 번호 생성기

제품 옵션을 선택하세요
옵션 선택:


(1) Thermocouple 선택하기:
없음(공란으로 비워두기) : None Thermocouple Models
-ITC : Non-Linearized Thermocouple Input
-LTC : Linearized Thermocouple Input

(2) Input Range 선택하기:
MV1 : ± 10 mV
MV2 : ± 50 mV
MV3 : ± 100 mV
MV4 : 0 to 10 mV
MV5 : 0 to 50 mV
MV6 : 0 to 100 mV
V1 : ± 1V
V2 : ± 5V
V3 : ± 10V
V4 : 0 to 1V
V5 : 0 to 5V
V6 : 0 to 10V
V7 : ± 20V
V8 : 0 to 20V
C1 : 4 to 20 mA
C2 : 0 to 20 mA
RTD1 : -100 to 100°C (-148 to 212°F)
RTD2 : 0 to 100°C (32 to 212°F)
RTD3 : 0 to 200°C (32 to 392°F)
RTD4 : 0 to 600°C (32 to 1112°F)
RTD5 : 0 to 400°C (32 to 752°F)
RTD6 : 0 to 300°C (32 to 572°F) 120 Ohm Ni.
P1 : 0 to 100 Ohm
P2 : 0 to 500 Ohm
P3 : 0 to 1 k Ohm
P4 : 0 to 10 k Ohm
J : -100 to 760°C (-148 to 1400°F) Non-Linearized Type J Thermocouple
K : -100 to 1350°C (-148 to 2462°F) Non-Linearized Type K Thermocouple
T : -100 to 400°C (-148 to 752°F) Non-Linearized Type T Thermocouple
E : 0 to 900°C (32 to 1652°F) Non-Linearized Type E Thermocouple
R : 0 to 1750°C (32 to 3182°F) Non-Linearized Type R Thermocouple
S : 0 to 1750°C (32 to 3182°F) Non-Linearized Type S Thermocouple
B : 0 to 1800°C (32 to 3272°F) Non-Linearized Type B Thermocouple
N : -100 to 1300°C (-148 to 2372°F) Non-Linearized Type N Thermocouple
J1 : 0 to 760°C (32 to 1400°F) Linearized Type J Thermocouple
J2 : -100 to 300°C (-148 to 572°F) Linearized Type J Thermocouple
J3 : 0 to 500°C (32 to 932°F) Linearized Type J Thermocouple
K1 : 0 to 1000°C (32 to 1832°F) Linearized Type K Thermocouple
K2 : 0 to 500°C (32 to 932°F) Linearized Type K Thermocouple
K3 : -100 to 1350°C (-148 to 2462°F) Linearized Type K Thermocouple
K4 : 0 to 1200°C (32 to 2192°F) Linearized Type K Thermocouple
T1 : -100 to 400°C (-148 to 752°F) Linearized Type T Thermocouple
T2 : 0 to 200°C (32 to 392°F) Linearized Type T Thermocouple
E : 0 to 1000°C (32 to 1832°F) Linearized Type E Thermocouple
R : 500 to 1750°C (932 to 3182°F) Linearized Type R Thermocouple
S : 500 to 1750°C (932 to 3182°F) Linearized Type S Thermocouple
B : 500 to 1750°C (932 to 3182°F) Linearized Type B Thermocouple
N : -100 to 1300°C (-148 to 2372°F) Linearized Type N Thermocouple
참고: 제품 구성 시 ‘판매 상담’으로 표시되어있는 제품은 영업부와 상담하십시오.

제품 메뉴얼:

다운로드 French Version - Régulateurs de process et de température
다운로드 Isolated DIN Rail Mount 2-WireTrasmitters
We noticed you are from the US. Visit your local site for regional offers and live support.